An integrated experimental-computational framework for elasto-plastic characterization and spatial mapping of canine bone properties.

中文关键词(术语机标,非人工翻译):外科手术 · 影像诊断 · 行为学

期刊PloS one
发表日期2026-10-23
物种犬
DOI10.1371/journal.pone.0361283
PMID42912822

摘要

Bone is a hierarchical and heterogeneous bio-composite material, with cortical and trabecular regions exhibiting distinct mechanical behaviors across scales. Patient-specific Finite Element Analysis (FEA) derived from medical images is increasingly used in both human and veterinary medicine to predict bone mechanical behavior under various loading conditions, assess fracture risk, and evaluate treatment outcomes. However, due to the complexity associated with measuring full elasto-plastic bone properties across multiple scales and bridging microscale properties to macroscale models, simplified material definitions are often adopted in FEA simulations. Such simplifications may produce unrealistic mechanical responses and fail to capture permanent microscopic and macroscopic deformations that occur when stresses exceed the bone yield point, particularly in implant design applications. This study presents an integrated experimental-computational framework for generating continuum material maps as a function of density from tissue-scale characterization of the canine femur. High-depth spherical nanoindentation combined with Genetic Algorithm (GA)-based inverse optimization was conducted to extract mechanically consistent elasto-plastic properties of cortical and trabecular bone from load-displacement responses influenced by post-yield contact uncertainties. Trabecular tissue-scale properties were then assigned to Representative Volume Elements (RVEs) reconstructed from micro-Quantitative Computed Tomography (μQCT) data and homogenized to account for architecture-dependent effective behavior. Finally, optimized cortical and homogenized trabecular properties were correlated with density to establish compartment-specific material mapping relationships for whole-bone FEA simulations. The optimized responses showed good agreement with the experimental indentation measurements, supporting the capability of the proposed framework to generate mechanically informed material definitions for patient-specific bone FEA simulations. Overall, the proposed framework provides a pathway for translating localized experimental measurements into heterogeneous elasto-plastic material inputs for whole-bone FEA without explicitly resolving trabecular microarchitecture.

站内已收录开放获取全文,见下方。

全文 开放获取 · Open Access (cc-by, via Unpaywall) 中文机翻

PLOS One | https://doi.org/10.1371/journal.pone.0361283 2026年10月23日 1 / 25

开放获取 引用格式:Amirzade B, Zobaer T, Lapsley J, Kim D-G, Selmic LE, Nassiri A (2026) 用于犬骨特性弹塑性表征与空间映射的实验-计算一体化框架。PLoS One 21(10): e0361283. https://doi.org/10.1371/journal.pone.0361283 编辑:Alice Berardo,帕多瓦大学:Universita degli Studi di Padova,意大利 收稿日期:2026年6月11日 接受日期:2026年10月8日 发表日期:2026年10月23日 版权:© 2026 Amirzade 等。本文为开放获取文章,依据 Creative Commons Attribution License 条款发布,允许在任何媒介中无限制使用、分发和复制,前提是保留原作者和来源。数据可用性声明:本文包含复现研究结果所需的全部原始数据。这包括重现文章所报告全部发现所需的最小数据集,以及书面代码、相关元数据和方​​法学 研究论文 用于犬骨特性弹塑性表征与空间映射的实验-计算一体化框架 Behzad Amirzade 1,2 , Tareq Zobaer 1,2 , Janis Lapsley 3 , Do-Gyoon Kim 4 , Laura E. Selmic 3 , Ali Nassiri 1,2 * 1 美国俄亥俄州哥伦布市俄亥俄州立大学工程学院集成系统工程系,2 美国俄亥俄州哥伦布市俄亥俄州立大学仿真创新与建模中心,3 美国俄亥俄州哥伦布市俄亥俄州立大学兽医学院兽医临床科学系,4 美国俄亥俄州哥伦布市俄亥俄州立大学牙学院正畸科 * nassiri.3@osu.edu 摘要 骨是一种分级且异质的生物复合材料,皮质骨和松质骨区域在不同尺度上表现出不同的力学行为。源自医学影像的患者特异性有限元分析(FEA)在人类和兽医医学中日益广泛用于预测骨在各种载荷条件下的力学行为、评估骨折风险以及评价治疗效果。然而,由于跨多个尺度测量完整弹塑性骨特性以及将微观尺度特性桥接至宏观尺度模型的复杂性,FEA模拟中常采用简化的材料定义。此类简化可能产生不切实际的力学响应,且无法捕捉当应力超过骨屈服点时发生的永久性微观和宏观变形,尤其是在植入物设计应用中。本研究提出了一种实验-计算一体化框架,用于基于犬股骨组织尺度表征生成作为密度函数的连续介质材料图。采用高深度球形纳米压痕结合基于遗传算法(GA)的逆向优化,从受屈服后接触不确定性影响的载荷-位移响应中提取皮质骨和松质骨力学一致的弹塑性特性。随后将松质骨组织尺度特性赋予由微型定量计算机断层扫描(μQCT)数据重建的代表性体积单元(RVE),并进行均质化以考虑结构依赖的有效行为。最后,将优化的皮质骨和均质化松质骨特性与密度相关联,建立用于全骨FEA模拟的区室特异性材料映射关系。优化响应与实验压痕测量结果显示出良好的一致性,支持所提出框架生成

PLOS One | https://doi.org/10.1371/journal.pone.0361283 2026年10月23日 2 / 25 用于患者特异性骨有限元分析模拟的力学信息材料定义。总体而言,所提出的框架提供了一条途径,可将局部实验测量转化为全骨有限元分析的异质性弹塑性材料输入,而无需显式解析骨小梁微结构。1. 引言 骨是一种由有机相和矿物相组成的层级异质性材料,皮质骨和松质骨 compartment 表现出不同的密度、结构和力学行为[1,2]。准确表征这些分区对于开发可靠的有限元分析(FEA)本构模型至关重要,尤其是用于预测骨变形和骨折。这在临床上具有重要意义,因为从医学图像重建正越来越多地用于生成患者特异性骨模型以进行FEA,支持骨折风险评估、治疗评价与规划以及快速临床分诊。近期研究利用计算机断层扫描(CT)和微型定量计算机断层扫描(μQCT)图像生成受试者特异性骨FEA模型,以估计损伤和骨折风险[3–6]。在这些模型中,异质性材料属性通常使用Hounsfield单位(HU)、骨质量密度和弹性模量之间的关系来赋值,尤其是对于临床CT衍生的FEA。其他研究也使用基于HU的材料映射来表示骨刚度的空间变化,并提高FEA模拟中的解剖学真实性[6–8]。然而,这些模型的准确性在很大程度上取决于所选择的模量–密度关系。Pervez等[9]表明,不同的模量–密度方程可显著影响FEA预测,尤其是当这些关系并非骨特异性或未区分皮质骨和松质骨分区时。此外,许多骨FEA研究依赖文献中的经验性模量–密度方程,而非源自所建模标本实际局部骨结构的关系。因此,当前知识支持基于CT的异质性材料映射的重要性,但也表明需要在实验测量的组织特性与分区特异性材料赋值之间建立更强的联系,以实现高保真全骨FEA。骨的力学特性可在不同尺度上测量,从捕捉整体响应的大尺度压缩、拉伸或弯曲试验,到表征局部组织水平弹性和塑性行为的纳米压痕方法[10–12]。尽管人骨纳米压痕表征在湿态和干态条件下均有广泛报道[13–16],但犬骨的特定位点弹塑性特性,尤其是弹性模量和硬度之外的特性,仍然有限。犬骨研究主要集中在有限区域,如股骨头、远端干骺端或皮质骨干[17–22]。这一局限性在兽医应用中尤为相关,因为在这些应用中需要准确的材料属性来评估骨肉瘤等疾病中的骨强度和骨折风险[23,24]。犬骨也广泛用于肌肉骨骼研究;然而,详情。所有数据和支持材料已存入Zenodo,可通过以下链接访问:https://doi.org/10.5281/zenodo.22713213。资助:衷心感谢Morris Animal Foundation的资助(Grant # D22CA-511)。资助方在研究设计、数据收集和分析、发表决定或手稿准备中均无作用。竞争利益:作者声明不存在竞争利益。

PLOS One | https://doi.org/10.1371/journal.pone.0361283 2026年10月23日 3 / 25 物种特异性差异仍然重要,因为据报道犬骨小梁的弹性模量和疲劳强度低于人骨小梁[25,26]。许多既往骨纳米压痕研究使用Berkovich压头,主要针对人或其它非犬类物种,以获取弹性模量而非完整的应力-应变或屈服后行为。球形压头提供更大的初始弹性区域和更平滑、逐步演化的接触应力场,使得能够从弹性到屈服直至屈服后行为追踪力学响应[27]。其圆润的几何形状还可减少应力集中以及在脆性或对断裂敏感材料压痕过程中过早开裂或突然断裂的可能性。因此,目前通过球形纳米压痕获得的犬长骨部位特异性弹塑性性能信息有限,尽管这些性能对于准确的有限元分析建模很重要。尽管Hertzian和Oliver–Pharr压痕分析被广泛使用[28,29],但将球形纳米压痕载荷-位移数据转换为可靠的应力-应变曲线对于生物组织仍然具有挑战性。骨违反了许多这些分析模型所依据的假设,因为它是异质的、各向异性的、多孔的,并且可能表现出非完全弹性的卸载行为[30–33]。此外,球形压头下方复杂且不均匀的弹塑性应力场使得将压痕数据直接转换为代表性应力-应变曲线并非易事[34,35]。因此,需要一个数值分析框架,通过将实验载荷-位移响应与有限元分析预测相匹配,并提取更可靠的弹塑性材料性能,来规范化纳米压痕数据的解释。此外,准确的材质赋值仍然是源自CT图像的有限元分析模型中的主要挑战。在患者特异性全骨模拟中,图像分辨率通常不足以分辨骨小梁基质和骨小梁的局部微结构连接性。Guha等人[36]证明,直接在CT体素网格上实施的连续体有限元分析可以通过为CT体素赋予基于密度的材料属性来估计骨小梁模量,从而避免对骨小梁结构的显式分割。然而,他们的方法需要100 μm的优化网格尺寸。尽管该分辨率对于小的骨小梁感兴趣区域(ROI)是实用的,但其应用于全長骨模型(例如长度为200–300 mm)将导致数量级为百万单元的极其庞大的单元数量,并大幅增加计算成本,限制了其用于整骨患者特异性分析的可扩展性。因此,尽管直接由CT体素构建的高分辨率连续体有限元分析对于局部骨小梁模量估计是有用的,但将如此精细的体素或网格分辨率直接应用于患者特异性全骨骨折模拟仍然不切实际。这产生了对微观到连续体材料映射方法的需求,该方法将微观尺度性能和微结构效应均匀化为具有力学意义的连续体水平性能,适用于临床规模的犬长骨有限元分析。本研究旨在提出一条系统性路径:I)通过在不同解剖部位使用球形纳米压痕,实验表征犬长骨(具体为大品种犬股骨)骨小梁和皮质区域的微观尺度弹塑性响应;II)开发基于遗传算法(GA)的逆向优化框架,通过将实验响应与复现的有限元分析压痕模拟相关联,改进从力-位移数据中提取应力-应变行为;III)通过骨小梁均匀化和开发犬长骨隔室特异性模量-密度关系,将优化的微观尺度性能转换到连续体尺度。总之,这些目标支持临床CT衍生有限元分析模型的高保真弹塑性材料赋值,其中骨小梁微结构无法详细显式捕捉,并为骨折风险评估和生物力学模拟提供物理相关的材料输入。本工作的新颖性在于将这些实验和计算步骤整合到一个统一框架中,该框架将局部纳米压痕测量转换为用于全骨有限元分析的空间变化材料属性图,如图1所示。本文其余部分组织如下。首先,描述用于骨小梁和皮质骨微观尺度表征的纳米压痕实验设置和测试程序,随后从纳米压痕结果中提取弹塑性性能。接下来,呈现材料映射框架,包括

PLOS One | https://doi.org/10.1371/journal.pone.0361283 2026年10月23日 4 / 25 用于获得有效骨小梁特性的均匀化方案以及犬长骨模量-密度相关关系的建立。随后展示并讨论了实验结果、数值优化结果和材料分布图。最后,总结了本研究的主要结论及未来意义。2. 方法 2.1. 实验设置与流程 骨标本以干燥状态取自一只大型犬的股骨,由俄亥俄州立大学兽医临床科学系提供。使用配备金刚石切割片的Leco VC-50精密切割锯在不同位置切取六个标本。切片在真空条件下冷镶嵌于双组分Leco环氧树脂(Leco环氧树脂与固化剂按100:14质量比)中,以促进树脂渗入多孔骨结构并增强标本在制备和压痕过程中的稳定性。每个骨小梁基底部周围完整的环氧树脂支撑对于最小化机械伪影至关重要;包埋不完整可能导致骨小梁在压痕过程中像悬臂梁一样变形,从而可能对其力学特性产生不准确的测量。在室温下固化8–12小时后,使用Buehler EcoMet 3000半自动研磨/抛光机对镶嵌样品进行研磨和抛光。研磨依次使用600、800和1200目碳化硅砂纸进行,随后用3 μm金刚石抛光膏和0.05 μm胶体二氧化硅抛光。每步之间,样品用水和试剂级乙醇清洗并干燥,以最小化表面污染和抛光伪影。这些制备步骤用于逐步减少表面缺陷和表面粗糙度,并提高纳米压痕测量的一致性和可靠性,与先前骨纳米压痕研究中报道的制备方法一致[37,38]。代表性镶嵌样品及制备横截面的光学显微镜图像如图2所示。显微图像使用Olympus GX53倒置光学显微镜在明场(BF)模式下以100×放大倍数采集,配备PAXcam软件。图1. 所提出的集成实验-数值框架概览。工作流程包括使用球形纳米压痕进行材料表征;使用基于遗传算法的弹塑性参数逆向识别进行数据提取和后处理;使用RVE均匀化实现微观结构材料化;以及弹塑性材料映射。https://doi.org/10.1371/journal.pone.0361283.g001

PLOS One | https://doi.org/10.1371/journal.pone.0361283 2026年10月23日 5 / 25 球形纳米压痕测试使用MTS Nano-XP纳米压痕仪进行,配备直径158 μm、弹性模量345 GPa、泊松比0.29的蓝宝石球形压头。标准Nano-XP系统最大法向载荷容量为500 mN,理论力分辨率为50 nN,位移分辨率<0.1 nm[39]。使用内置光学显微镜选择压痕位点,以确保压痕置于目标骨区域内并远离可见缺陷或骨-环氧树脂界面。为最小化潜在的局部边界和约束效应,压痕位置主要根据表面质量选择, targeting清洁、光滑且视觉上完整的区域。未应用额外的解剖学或力学选择标准。在位移控制下应用定制的骨压痕方案,骨小梁的最大压痕深度为4000 nm,皮质骨为5000 nm。该方案由Kim等人描述[40]。附加图2. 环氧树脂中镶嵌的骨样品及相应光学显微照片。切片a–f分别取自(a)股骨头、(b)近端干骺端、(c)骨干——L、(d)骨干——T、(e)骨干——R和(f)远端干骺端。L、T和R分别表示纵向(平行于股骨轴线)、切向和径向。虚线表示大致切片位置和方向。切片(a)在θ ≈ 38°处获得。红框表示用于光学成像和纳米压痕的大致区域。标本直径(d s)约为35 mm。此处,φ表示股骨干直径,φ/2偏移表示用于实现径向压痕的近表面切片。比例尺代表250 μm。https://doi.org/10.1371/journal.pone.0361283.g002

PLOS One | https://doi.org/10.1371/journal.pone.0361283 2026年10月23日 6 / 25 测试参数包括允许漂移速率0.2 nm/s、表面接近距离1000 nm、表面接近速度10 nm/s以及稳定时间25 s。测试前,使用熔融石英对压头尖端进行校准[16]。所有测试均采用连续刚度测量技术进行。在该技术中,在施加负荷上叠加一个小振荡信号,以连续测定接触刚度随压痕深度的函数关系。在每个深度处,硬度由施加负荷和投影接触面积计算得出,而弹性模量则由测得的接触刚度和接触面积推导得出,并考虑压头的弹性特性。该方法能够实现机械性能的深度依赖性测量,特别适用于骨等异质性材料[41]。伦理声明。本研究中使用的标本由俄亥俄州立大学兽医学院提供,该学院在治疗前作为常规临床知情同意流程的一部分获取标准书面主人知情同意。

E ∗ = [ 1–ν 2 E + 1–ν i 2 E i ] –1 (1) 其中E和ν分别为样品的弹性模量和泊松比,而E i = 345 GPa和ν i = 0.29为压头的相应特性。一旦尖端校准完成,E * 可利用接触深度(h c )和h t 求得,详见S1附录(见第S1.1节)。小梁和皮质微结构上的代表性球形压痕标记也分别显示于图3B和3C中。球形压痕与锥形和棱锥形压痕存在根本性差异,因为球形尖端在几何上非自相似。在自相似压头中,接触几何形状随压入深度成比例缩放,而在球形压痕中,接触半径、投影接触面积和次表面应力场随压痕深度增加而连续且非线性演化[42,43]。接触几何形状的这种深度依赖性演化使得图3. 球形纳米压痕及代表性压痕印记。(A) 球形压头与样品接触的示意图,其中a为最大负荷下的投影接触半径,h c 为接触深度,h t 为总压痕深度,d为卸载后测量的残余压痕印记直径;(B) 小梁骨和(C) 皮质骨样品上纳米压痕印记的代表性显微照片。蓝色圆圈表示残余压痕印记。https://doi.org/10.1371/journal.pone.0361283.g003

PLOS One | https://doi.org/10.1371/journal.pone.0361283 2026年10月23日 7 / 25 加载响应与代表性压痕应变相关联。因此,球形压痕负荷-位移曲线可转换为压痕应力-应变响应,为按照Juliano等人[43]提出的方法评估骨组织作为半脆性材料的弹塑性行为提供了更合适的基础。压痕应力按施加负荷除以投影接触面积计算:

σ= ψP πa 2 =0.9 ( h t h c –1 ) P πa 2 (2) 其中a为投影接触半径,ψ= 0.9(ht/hc–1)为深度相关修正因子。随着压入过程的推进,ht/hc自然发生变化,使修正因子ψ能够反映从以弹性接触为主到弹塑性变形的逐渐过渡。据报道,该因子在纯弹性状态下约为0.9,并随塑性变形的发展而减小[43,44]。获得压入应力后,利用压入应力、弹性模量、接触几何、总压入深度、接触深度和校准投影接触面积之间的关系计算真应变的相应表达式。压入应变计算的完整推导和所用方程见S1附录S1.1节。根据实验纳米压入数据计算出压入应力和应变后,从所得曲线估算弹性模量和表观初始屈服点。表观初始屈服点定义为偏离初始线性响应的起点。按照Nesbitt等人[45]描述的导数方法,从曲线早期部分将该点确定为二阶导数零交叉点中斜率最大的位置。二阶导数用于识别一阶导数中的候选驻点,即曲线斜率演化发生改变的位置。该判据识别斜率从初始线性响应到非线性状态的转变。在本研究中,搜索区域限于应变低于1.5%,以确保所识别点对应初始弹性到非线性的转变,而非后期屈服后行为。由于实验推导的压入应力-应变曲线包含逐点局部振荡,尤其是在屈服后,直接数值微分可能因微分放大数据中的局部变化而不稳定。因此,在计算一阶和二阶导数之前,对数据拟合12次多项式以获得响应的平滑表示。然后,将弹性模量确定为在所识别表观屈服点之前紧邻的0.5%应变区间上最小二乘线性拟合的斜率。超出弹性状态后,对计算所得压入应力-应变响应的直接解释因真实接触面积估算的不确定性而变得复杂。这些不确定性可能源于塑性变形机制,包括材料在压头周围堆积的pile-up和接触区域周围表面下陷的sink-in,以及实验伪影,如偏离理想压头几何形状和局部表面粗糙度。因此,采用逆向数值框架来减轻这些屈服后不确定性的影响,并获得更稳定且更具物理代表性的塑性参数。在该方法中,骨样品的弹塑性性能使用基于GA的逆向优化框架结合FEA进行估算。纳米压入模拟在ABAQUS [46]中进行,优化程序使用自研MATLAB [47]代码实现。对于FEA,骨被建模为各向同性弹性材料,由杨氏模量和泊松比定义,以及由屈服应力及其对应应变的三个数据点表征的各向同性硬化。塑性模型遵循经典各向同性(von Mises)塑性及各向同性硬化。该公式未考虑静水应力对屈服的影响,此处采用该公式是为了在逆向识别框架内实现计算可处理性。泊松比对提取模量的影响不是本研究的重点。因此,骨组织使用平均值ν = 0.3,这与Asgari等人[48]一致,他们报告将ν从0.2变化到0.45使皮质骨估计模量变化18.2%,松质骨变化19.5%。在压头与

PLOS One | https://doi.org/10.1371/journal.pone.0361283 2026年10月23日 8 / 25 样本,而硬接触则定义在法向方向上,以避免穿透并允许接触压力形成[33]。压头运动通过参考点(RP)控制,在参考点上施加规定的垂直位移。骨域的底部边界采用ENCASTRE边界条件进行约束。压入过程采用二维轴对称模型模拟,球形压头因其刚度显著高于骨组织而被表示为刚性表面,使压头变形可忽略不计。骨域采用2601个CAX4R四节点轴对称四边形减缩积分单元进行离散化。通过减小网格尺寸直至参考点处记录的反作用力在代表性测试案例中收敛至稳定值,进行了网格敏感性分析。此外,在接触区域应用了局部网格细化以提高压入响应的准确性。网格采用空间渐变,细化接触区域的单元边长约为1 μm,远离压入部位的较粗区域单元边长可达约10 μm。FEA纳米压入试验的加载阶段通过在静态非线性条件下逐步施加实验最大压入深度进行模拟,参考点处的反作用力从ABAQUS输出中提取。图4A显示了用于模拟球形纳米压入试验的静态轴对称FEA设置。图4. 用于球形纳米压入的FEA模拟与基于GA的逆向优化框架。(A)复现纳米压入实验的FEA模拟设置,显示离散化几何体在接触区域附近具有细化网格以及压入后的应力云图。von Mises应力云图与构成模型中所采用的公式一致,仅用于可视化模拟应力场。(B)用于从纳米压入数据确定弹塑性材料属性的逆向优化框架流程图。优化后的FEA载荷(P opt)由规定压入位移下参考点处的反作用力获得,并在优化过程中与实验载荷-深度响应进行比较。https://doi.org/10.1371/journal.pone.0361283.g004

PLOS One | https://doi.org/10.1371/journal.pone.0361283 2026年10月23日 9 / 25 从每次FEA模拟中提取的主要输出为参考点处反作用力随规定压入深度变化的函数。该模拟载荷-深度响应用于逆向优化中,通过与相应的实验响应进行比较来识别弹塑性材料参数。进一步的FEA实现细节见S1附录(第S1.2节)。塑性响应采用三个屈服应力-应变控制点定义:

x= [ σ 0 y ,ε 0 y ,σ 1 y ,ε 1 y ,σ 2 y ,ε 2 y ] (3) 其中(σ y 0 , ε y 0)代表初始屈服点,(σ y 1 , ε y 1)描述为表征屈服后硬化响应演化而引入的中间控制点,(σ y 2 , ε y 2)为分析应变范围内的终点。该中间点提供了描述非线性硬化的灵活性,而非代表单独的物理屈服事件。这三个点定义了ABAQUS中的分段各向同性硬化行为,其中ε i y(i= 0, 1, 2)

表示相应的总单轴应变。这些参数作为优化设计变量。GA通过最小化纳米压入获得的实验载荷-深度响应与相应FEA预测响应之间的差异来迭代更新这些参数,从而识别出优化后的弹塑性材料属性。该框架如图4B所示。为确保物理上真实的弹塑性响应,优化后的应力-应变点被约束为遵循单调硬化行为:

ε 0 y ≤ε 1 y ≤ε 2 y σ 0 y ≤σ 1 y ≤σ 2 y (4) 这些约束基于观察到的纳米压入应力-应变曲线行为,该曲线显示应力与应变之间呈正相关。终止应变限定为3%,所有模拟均保持在校准的硬化范围内,避免超出最终定义点进行外推。逆向优化问题通过最小化实验与FEA预测载荷-深度曲线之间的均方误差(MSE)来构建:

min x J ( x ) = 1 N s N s ∑ i=1 [ ̃ P exp ( h i ) – ̃ P opt ( h i ,x ) ] 2 (5) 其中 P̃ exp 和 P̃ opt 分别为在压痕深度 h i 处通过12次多项式拟合获得的实验和模拟压痕载荷,N s = 1000 为 0 到 h exp max 之间均匀分布的样本点数,用于曲线比较。多项式拟合为两种响应提供了平滑表示,并使得在相同穿透深度下进行直接比较成为可能。这对于评估优化问题的目标函数变得重要。多项式阶数敏感性评估见 S1 附录第 S1.1 节。遗传算法迭代更新材料参数,直到达到最大15代或最佳适应度值连续五代无进一步改善。选择该停止策略是为了在收敛精度与计算成本之间取得平衡,因为每次适应度评估都需要单独的有限元分析模拟。由于遗传算法本质上是随机的,此处不需要梯度信息。这种方法的优势在于,为此类高度非凸优化问题推导梯度表达式将极其复杂。为评估优化可重复性,使用不同初始种群对代表性中央骨干皮质切向测试独立优化了三次。遗传算法实现和可重复性评估的详细信息见 S1 附录(见第 S1.2 节)。

PLOS One | https://doi.org/10.1371/journal.pone.0361283 2026年10月23日 10 / 25 2.3. 微观到连续尺度材料映射 为将组织尺度力学性能与常规有限元分析的连续体水平材料输入相衔接,将优化后的材料参数纳入均匀化方案和材料映射框架。局部纳米压痕测量结果并未直接外推至整个骨骼;而是将其用作区域特异性组织性能,并结合区域 μQCT 衍生的结构 and 密度信息,建立隔室特异性连续体关系。由于皮质骨与松质骨相比具有相对致密的微观结构,假设其连续体水平力学响应与其组织水平性能密切相关。因此,本研究中优化后的微观尺度皮质骨性能被认为代表连续体尺度(即宏观尺度)皮质材料响应。相比之下,松质骨具有高度多孔且结构复杂的结构,使得直接的组织到连续体等效不适用。因此,从犬股骨每个 ROI 的 μQCT 图像中随机提取两个代表性体积单元(RVE),以捕捉区域特异性松质骨结构并通过均匀化推导有效弹性模量。μQCT 图像以 20 μm 的空间分辨率采集,选择边长为 2 mm 的立方体 RVE 以提供局部松质骨微观结构的连续体尺度表示。尽管 RVE 是随机选择的,但选择它们是为了捕捉每个 ROI 内松质骨特征的重复微观结构模式。选择旨在反映与纳米压痕所检查的松质骨结构相当的松质骨结构,同时纳入 μQCT 图像中识别的额外区域结构。因此,RVE 不一定与纳米压痕位点在空间上重合。纳米压痕提供组织尺度性能,而 RVE 捕捉依赖结构的有效行为。图 5A 展示了犬股骨不同解剖位置处所选 ROI 及其对应的 RVE。每个 RVE 使用多边形网格体素化算法进行体素化,并离散为规则有限元单元胞 [49]。对每个 RVE 施加六个独立的单位应变工况,包括三种正应变和三种剪切加载模式,以计算均匀化刚度张量和相应的有效弹性性能。尽管假设实体骨组织为局部各向同性,但均匀化 RVE 响应不受各向同性约束。六个独立加载工况允许确定完整的均匀化刚度张量,从而捕捉松质骨结构的方向依赖性弹性响应。体积为 |Y| 的单元胞的均匀化刚度张量的有限元分析近似由下式给出:

E H ijkl = 1 |Y| N e ∑ e=1 (u A(ij) e ) T k e u A(kl) e (6) 在该方程中,N e 为单元数,k e 为单元刚度矩阵,u A(ij) e 和 u A(kl) e 为与所施加单位应变场相关的单元位移场 [50]。假设构成每个体素的实体骨组织为局部各向同性弹性,体积为 Ω e 的单元的单元刚度矩阵为:

k e = ∫ Ω e B T CBdΩ e (7) 此处 B 为应变-位移矩阵,C 为实体骨组织的本构矩阵。本构矩阵使用 Lamé 参数定义:

λ= νE ( 1+ν)(1–2ν ) ,μ= E 2(1+ν) (8) 其中 E 和 ν 分别为组织尺度的弹性模量和泊松比。注意,Lamé 参数直接由 E 和 ν 推导而来,仅用于定义用于均匀化的单元级本构矩阵。

PLOS One | https://doi.org/10.1371/journal.pone.0361283 2026年10月23日 11 / 25 在本工作中,采用了 Dong 等人 [51] 针对多孔材料提出的均匀化方法。该方法涉及使用体素化算法将结构投影到具有三维实体单元的有限元网格上。所有微结构均被离散为具有 100 × 100 × 100 个单元的单元胞。有关 RVE 提取、均匀化公式以及所得正交各向异性有效特性的更多信息,见 S1 附录的 S1.3 节。均匀化后的弹性特性用于建立连续尺度模量–密度关系,而相应的屈服和屈服后参数则随后通过依赖 E 的插值程序赋值。均匀化之后,开发了一种基于密度的材料映射方案(如图 5B 所示),用于为有限元模型赋予空间变化的弹性特性。该方法允许将小梁骨区室表示为等效连续体,而不是显式解析的多孔结构,后者使用常规 CT 分辨率无法实现。注意,使用标准体模校准将 CT 强度转换为校准密度。对于小梁骨,将来自不同 ROI 的每个 2 × 2 × 2 mm³ RVE 的平均 HU 转换为表观密度(ρ_app),并与其均匀化有效模量 E_eff^trab 配对,使得每个 RVE 提供一个 E_eff^trab–ρ_app 数据点。对于皮质骨,每个皮质区域的平均 HU 类似地转换为 ρ_app,并与优化的图 5. 微观到连续尺度材料映射框架。(A) 从股骨头(RVE 11 和 RVE 12)、股骨颈(RVE 21 和 RVE 22)、大转子(RVE 31 和 RVE 32)、远端干骺端(RVE 41 和 RVE 42)以及远端髁(RVE 51 和 RVE 52)提取的 RVE,其中第一个索引表示解剖区域,第二个索引区分从该区域提取的两个 RVE;以及 (B) 用于推导区室特异性 E(HU) 关系和用于 FEA 的空间一致弹塑性材料特性的工作流程。https://doi.org/10.1371/journal.pone.0361283.g005

PLOS One | https://doi.org/10.1371/journal.pone.0361283 2026年10月23日 12 / 25 纳米压痕衍生的模量,以获得 E_cort–ρ_app 关系。根据 Helgason 等人 [52] 的建议,使用幂律关系来描述小梁骨和皮质骨的 E–ρ_app 相关性:

E(ρ_app)= { α_trab ρ_app^β_trab α_cort ρ_app^β_cort (9) 其中 α 和 β 是分别针对小梁骨和皮质骨区室确定的拟合系数。这些区室特异性的 E–ρ_app 关系可与体模衍生的 ρ_app–HU 校准相结合,以定义 E_eff^trab(HU) 和 E_cort(HU),从而能够为皮质骨和小梁骨区域进行患者特异性材料赋值。因此,最终的区室特异性弹性模量图可定义为:

E(HU)= { f_trab ( ρ(HU) ) HU<HU_th f_cort ( ρ(HU) ) HU≥HU_th (10) 其中 f_trab 和 f_cort 分别为小梁骨和皮质骨的 E–ρ_app 函数,HU_th 是分隔小梁骨主导区域和皮质骨主导区域的阈值。该阈值依赖于协议,并可能随 CT 采集设置、重建参数和校准程序而变化;因此,在可获得校准体模数据时应使用其确定该阈值。塑性参数也可以作为 E(HU) 的函数进行插值,以赋予空间一致的弹塑性特性。对于 FEA 材料赋值,E(HU) 被用作 CT 强度与优化塑性参数之间的中间环节。每个实验校准的弹性模量均与一组相应的塑性参数相关联,这些参数通过逆向优化获得,包括初始屈服和随后的硬化应力–应变点。因此,当针对给定 HU 区间计算出的模量与其中一个校准值对应时,直接赋予相关的优化塑性参数集。对于产生中间模量值的 HU 区间,相应的塑性参数通过在两个相邻校准材料集之间插值获得。对于一般塑性参数 p,这可表示为:

p(Ei)=pj+(Ei–Ej)/(Ej+1–Ej)×(pj+1–pj) (11) 其中Ei为目标弹性模量,Ej和Ej+1为相邻的已校准弹性模量,pj和pj+1为它们对应的优化塑性参数。该过程分别应用于每个参数p∈{σy0, εy0, σy1, εy1, σy2, εy2},使每个HU区间均被赋予完整的弹塑性材料卡片。该映射假设在每个骨区内,优化塑性参数在实验校准的材料状态之间平滑变化,且其与相应弹性模量的关联在已校准范围内具有代表性。所有插值材料集均保持相同的本构公式,皮质骨与松质骨特性分别处理。因此,首先利用HU通过已建立的E(HU)关系确定E,然后通过在相邻已校准材料集之间进行E依赖性插值来赋予相应的塑性参数。3. 结果 3.1. 应力–应变曲线 由纳米压痕获得的应力–应变曲线如图6所示。对每个样品进行多次压痕以确保实验可重复性,并排除离群值。球形压痕衍生的应力–应变曲线显示出明显的位点依赖性力学行为,反映了骨组织的异质性。

PLOS One | https://doi.org/10.1371/journal.pone.0361283 2026年10月23日 13 / 25 尽管在同一解剖区域内的压痕点之间观察到变异性,但每个位点内的响应总体遵循相似趋势,表明组织特性在给定位置内比在不同解剖区域之间更为一致。3.2. 弹塑性参数 直接由实验计算得到的弹塑性材料特性以及通过逆向优化程序获得的等效参数如图7所示。在每个解剖位置,分析了3–5次重复压痕 图6. 由球形针尖纳米压痕衍生的应力–应变曲线。在屈服点之后观察到噪声和振荡增加,主要是由于屈服后变形过程中接触面积估计的不确定性更大。注:红色圆圈表示CT图像上的近似压痕位置,不代表单个压痕点。https://doi.org/10.1371/journal.pone.0361283.g006

PLOS One | https://doi.org/10.1371/journal.pone.0361283 2026年10月23日 14 / 25,报告的材料参数以相应的均值±SD(即标准差)表示。这些定量材料参数进一步证明了所检查股骨内的区域变异。实验衍生的弹性模量通常高于优化值,平均绝对对称差异约为15.97%,表明中度一致性。该差异可能源于直接从表观屈服点附近的局部斜率估计模量。在该转变附近,斜率对平滑、多项式拟合、局部振荡和应变窗口选择敏感,可能高估刚度。对于代表性皮质骨测试,将多项式阶数从12降至8仅使提取的弹性模量变化1.1%,而表观初始屈服应力和应变分别变化9.1%和8.3%。更多细节见S1附录第S1.1节。在测试区域中,来自中央骨干的纵向皮质骨样本显示出最高的弹性模量,优化值为14.80±0.49 GPa。径向和切向方向较低的模量反映了皮质骨的取向依赖性刚度。优化后的初始表观屈服应变聚集在狭窄范围内,主要在0.6–0.7%左右。这种有限变异是预期的,因为压痕应变代表局部接触响应而非真正的连续体 图7. 由纳米压痕实验和优化框架获得的弹塑性材料特性。(A) 弹性模量,(B) 初始和最大表观屈服应变,(C) 初始和最大表观屈服应力,(D) 实验和优化数据的平均可重复性,以变异系数CV(%)表示。每个位置的样本量标注于(A)中相应组上方,并适用于(B)和(C)。缩写:Cort.,皮质骨;Trab.,松质骨;meta.,干骺端;L,纵向;T,切向;R,径向;Exp.,实验;Opt.,优化;CV,变异系数;SD,标准差。https://doi.org/10.1371/journal.pone.0361283.g007

PLOS One | https://doi.org/10.1371/journal.pone.0361283 2026年10月23日 15 / 25 应变场,高度不均匀的应变集中在球形压头下方。因此,与初始表观屈服应变相比,模量、屈服应力和屈服后响应方面的区域差异更为明显。相比之下,优化后的最大表观屈服应变显示出更大的变异,范围约为1.98%至2.49%。最高值出现在股骨头的骨小梁中(2.49 ± 0.11%),这与骨小梁具有更大的顺应性和变形能力相一致。优化后的屈服应力参数比屈服应变表现出更明显的解剖部位依赖性。最高的承载响应出现在中央骨干的纵向皮质方向,优化后的初始表观屈服应力为101.27 ± 8.71 MPa,最大表观屈服应力为254.28 ± 13.05 MPa。优化后的最大表观应力通常高于直接从实验中估算的值,平均绝对对称差约为22.33%。与弹性模量估算值相比,这一较大的差异反映了屈服后区域更大的离散性和不确定性。实验表观屈服后数值不应被解释为优化中间和终端硬化参数的直接对应值,后者是通过力-位移响应反演辨识得到的。为了量化实验导出参数和优化参数的可重复性和可靠性,使用相应的均值和标准差计算了每个解剖区域的变异系数(CV)。然后将区域CV值汇总为所有区域的平均CV ± 标准差,而详细的区域特异性CV值见S1附录的表S2和表S3。对于优化参数,平均CV值显示出中等程度的变异性,范围约为10.8%至19.6%。弹性模量显示出相对一致的结果,优化框架的平均CV值为10.81 ± 5.32%。屈服相关参数显示出略高的变异性,尤其是最大表观屈服应变,优化后的CV值为18.65 ± 4.98%。优化值中观察到的变异性表明,该框架保留了解剖和组织水平的差异,而非过度平滑材料响应。优化后的塑性参数和MSE值见表1。这些参数可用于微观尺度计算框架中,以定义本构模型的塑性区域,并支持基于最大表观应力和应变的潜在损伤起始准则。对于每个解剖区域,将优化后的弹性模量和塑性应力-应变参数组合起来,定义区域特异性的弹塑性材料模型。通过比较实验和优化后的力-位移响应来评估优化参数集的质量。区域特异性MSE值范围为2.66至9.88 (mN)²,表明优化模型密切再现了实验压痕响应。与相应的力水平相比,这些误差较小,表明优化程序提供了可靠的拟合,并能提取力学一致的 表1. 基于GA的反演优化框架得到的优化塑性参数。区域 骨类型 优化塑性参数 MSE (mN)² σ0y (MPa) ε0y (%) σ1y (MPa) ε1y (%) σ2y (MPa) ε2y (%) FH 皮质 55.4 ± 10.6 0.66 ± 0.07 170.9 ± 21.4 1.44 ± 0.41 205.5 ± 25.6 2.47 ± 0.39 4.44 ± 2.83 骨小梁 43.7 ± 8.7 0.67 ± 0.16 113.2 ± 27.4 1.26 ± 0.38 191.1 ± 28.6 2.49 ± 0.11 5.75 ± 3.31 PM 皮质 66.4 ± 7.5 0.67 ± 0.06 162.6 ± 37.9 1.13 ± 0.08 235.4 ± 26.9 1.98 ± 0.32 2.75 ± 0.93 CD 皮质 – L 101.3 ± 8.7 0.68 ± 0.04 230.6 ± 27.5 1.17 ± 0.10 254.3 ± 13.0 2.23 ± 0.50 4.98 ± 0.56 皮质 – T 32.5 ± 5.1 0.53 ± 0.05 108.8 ± 57.4 1.14 ± 0.15 204.9 ± 13.6 2.35 ± 0.36 2.66 ± 1.83 皮质 – R 23.3 ± 4.2 0.45 ± 0.08 136.0 ± 29.4 1.39 ± 0.60 212.2 ± 28.9 2.18 ± 0.63 5.70 ± 4.03 DM 皮质 47.5 ± 9.3 0.61 ± 0.09 138.5 ± 18.3 1.06 ± 0.22 157.1 ± 26.6 2.06 ± 0.42 5.28 ± 2.66 骨小梁 39.1 ± 9.7 0.62 ± 0.03 144.0 ± 17.1 1.15 ± 0.16 191.3 ± 19.7 2.21 ± 0.57 9.88 ± 16.06 参数报告了股骨头(FH)、近端干骺端(PM)、中央骨干(CD)和远端干骺端(DM),包括初始屈服、中间硬化、最大表观应力-应变值以及相应的拟合MSE。注:对于CD皮质样本,L = 纵向,T = 切向,R = 径向。https://doi.org/10.1371/journal.pone.0361283.t001

PLOS One | https://doi.org/10.1371/journal.pone.0361283 2026年10月23日 16 / 25 各区域的弹塑性参数。代表性比较显示在整个压痕深度范围内吻合良好,详见S2图及S1附录第S1.2节。对于代表性皮质骨试验,三次采用不同初始种群的独立GA运行产生了可比的力-位移拟合结果(MSE = 1.67–1.91 (mN)²)。初始屈服参数和终末硬化应力变异性较低(CV = 0.55–1.12%),而中间硬化参数变异性较大(约13%)。更多细节见S1附录第S1.2节。3.3 连续尺度材料属性 HU–ρ_app关系采用在μQCT扫描期间扫描的两个已知密度校准体模(密度分别为0.25和0.75 g/cm³)进行估算。所得校准方程为:

ρ_app = 7×10⁻⁴ HU* + 3.57×10⁻² (12) 其中HU*为方案依赖性HU值。尽管HU*–ρ_app校准具有方案依赖性,但将HU*转换为ρ_app可使均匀化有效模量E_eff通过E–ρ_app关系表达,从而减少对原始图像强度的直接依赖。小梁RVE最初赋予E = 6.53 GPa和ν = 0.3,基于股骨头小梁样本的优化属性。对于从远端干骺端提取的RVE 41和RVE 42,采用E = 7.74 GPa和ν = 0.3以代表相对多孔的皮质-小梁过渡区。选择均匀化获得的最大方向有效模量作为主要承载模量,并与相应的表观密度值相关联,以定义用于材料赋值的E_trab_eff–ρ_app关系。对于小梁骨和皮质骨,表观密度均由2 × 2 × 2 mm³的μQCT衍生子体积计算。这些相关性如图8所示。详细均匀化结果见S1附录(表S4)。随后使用拟合的E–ρ_app关系为小梁主导区和皮质主导区赋予空间变化的弹性属性。为每个区分别定义相关性,以考虑其有效E–ρ_app响应的差异。最终的分区特异性弹性模量图定义为:

E(ρ_app) = { 7.584 ρ_app^1.273 小梁 8.904 ρ_app^2.035 皮质 (13) 图8. 通过幂律曲线拟合得出的模量-密度相关性。(A) 小梁骨和(B) 皮质骨区域。小梁数据点代表μQCT衍生的RVE表观密度与均匀化获得的有效模量的配对。皮质数据点代表μQCT衍生的表观密度与优化获得的相应区域特异性平均弹性模量的配对。所得拟合关系用于定义分区特异性连续尺度材料属性。https://doi.org/10.1371/journal.pone.0361283.g008

PLOS One | https://doi.org/10.1371/journal.pone.0361283 2026年10月23日 17 / 25 在本研究中,考虑CT成像方案和观察到的HU*范围,将式12和式13合并,以定义弹性模量图作为HU*的函数。HU* ≥ 500的体素视为皮质主导区,而HU* < 500的体素视为小梁主导区。因此,弹性模量图定义为:

E(HU*) = { 7.584 (7×10⁻⁴ HU* + 3.57×10⁻²)^1.273 HU* < 500 8.904 (7×10⁻⁴ HU* + 3.57×10⁻²)^2.035 HU* ≥ 500 (14) 除弹性映射外,还将优化的塑性参数插值为E(HU*)的函数,以在有限元模型中赋予空间一致的弹塑性属性。因此,屈服和屈服后参数根据由分区特异性E(HU*)关系获得的局部弹性模量进行赋值,使弹性和塑性响应均能反映区域组织异质性。因此,所得材料定义包括E以及σ_y0、ε_y0、σ_y1、ε_y1、σ_y2和ε_y2。分配给HU*的完整弹塑性参数集

各区间汇总于表2。对于每个HU*区间,利用该区间的中点HU*值通过式14计算代表性弹性模量,并通过式11所述的E依赖性插值获得相应的塑性参数。为展示连续尺度材料赋值,使用压痕导出的骨组织模量值作为均匀化输入,对犬股骨RVE进行颜色映射,如图9A所示。随后为相应的连续尺度单元赋予每个RVE获得的均匀化属性。均匀化连续单元的有效弹性模量略低于组织水平模量,因为它考虑了孔隙率和骨小梁结构的影响。随后从μQCT图像中分割出完整股骨,并生成单元尺寸为1.0 mm的自适应网格以展示材料赋值,如图9B所示。对于每个单元,将该单元内所含μQCT体素的平均灰度值近似作为材料赋值的等效CT灰度值。然后使用式14为连续尺度犬股骨模型赋予区室特异性弹性模量,同时使用式11和表2所述的E依赖性插值程序赋予相应的塑性参数。尽管图9中的空间分布图以弹性模量进行可视化,但每个HU*区间代表表2中报告的相应完整弹塑性材料参数集。为证明该方法的广泛适用性,将所提出的材料映射应用于其他基于临床CT的犬肱骨、胫骨和桡骨模型进行宏观尺度有限元分析,如图10所示。由于 表2. 使用区室特异性E(HU*)关系和优化塑性参数的E依赖性插值进行连续有限元分析的弹塑性材料属性。HU*范围 骨类型 E (GPa) σ0y (MPa) ε0y (%) σ1y (MPa) ε1y (%) σ2y (MPa) ε2y (%) 80–289 骨小梁 HU* < 500 0.76 11.8 1.073 18.8 1.382 24.0 2.057 290–499 1.72 18.5 1.075 30.4 1.386 38.8 2.062 500–680 皮质骨 HU* ≥

500 1.74 18.8 1.076 30.9 1.386 39.4 2.072 681–861 2.89 31.3 1.080 52.4 1.392 66.9 2.073 862–1041 4.33 46.8 1.081 74.7 1.393 95.1 2.073 1042–1222 6.06 65.6 1.082 103.4 1.393 131.8 2.080 1223–1402 8.10 87.9 1.085 138.1 1.398 176.5 2.080 1403–1583 10.43 113.1 1.084 177.9 1.398 227.1 2.083 1584–1763 13.06 142.2 1.088 207.1 1.403 239.4 2.087 1764–1950 16.00 175.1 1.095 237.6 1.411 249.2 2.100 https://doi.org/10.1371/journal.pone.0361283.t002

PLOS One | https://doi.org/10.1371/journal.pone.0361283 2026年10月23日 18 / 25 这些数据集中的临床CT体素尺寸约为500–900 μm,无法明确分辨骨小梁微结构。因此,骨小梁区域使用等效连续属性表示,而非直接建模单个骨小梁。对于每个HU*区间,弹性模量由区室特异性关系确定,相应的屈服和屈服后参数使用式11和表2所述的E依赖性插值程序赋值。所得全骨网格中,肱骨包含782,856个四面体单元(单元尺寸0.8 mm),胫骨包含671,302个(0.8 mm),桡骨包含985,394个(0.85 mm)。代表性股骨模型包含1,121,156个单元(1.0 mm)。4. 讨论 本研究开发的实验-数值集成路径提出了一种材料映射方法,用于在常规患者特异性有限元分析中为骨组织赋予部位特异性和区室特异性弹塑性属性。图9. 犬股骨中的RVE均匀化与连续尺度材料赋值。(A) 从股骨不同解剖区域提取的RVE,使用压痕导出的组织水平弹性模量进行颜色映射,并均匀化以获得相应的有效弹性模量E trab eff。(B) 用于展示基于HU*–ρapp关系的区室特异性材料赋值的连续尺度股骨网格。连续建模时填充了骨小梁孔隙,并以米色显示1-mm皮质壳(E ≈ 10.60 GPa)。RVE中的青蓝色区域仅为孔隙-骨过渡处的可视化伪影;每个RVE在均匀化前被赋予单一模量。https://doi.org/10.1371/journal.pone.0361283.g009

PLOS One | https://doi.org/10.1371/journal.pone.0361283 2026年10月23日 19 / 25 结果表明,球形纳米压痕能够捕捉不同解剖部位的组织水平力学响应,而基于遗传算法的逆向优化流程降低了对屈服后接触面积估算的依赖。与直接解读压痕获得的应力-应变曲线相比,该方法提供了更稳定且力学一致的材料参数,尤其是在屈服后区域。通过将优化后的组织尺度属性与RVE均质化及E–ρ表观相关性相结合,所提出的路径将微观尺度测量与连续尺度材料图谱联系起来,用于从临床CT图像重建的患者特异性FEA模型,在这些模型中骨小梁微结构无法被显式解析。观察到的空间变异强调了进行全面区域特异性表征的重要性,因为不同解剖部位承受着不同的加载模式、加载方向和功能需求。这些局部力学环境可影响组织排列、密度、矿化程度和整体力学响应[53–55]。因此,测试多个区域为捕捉骨异质性和为FEA开发空间信息材料属性提供了更具代表性的基础。另一个主要观察结果是,屈服开始后计算出的应力-应变曲线离散度增加并出现振荡行为。虽然初始弹性区域表现出相对更平滑和更一致的行为,但屈服区和屈服后区域表现出更大的波动。这些振荡可能源于局部塑性变形、微结构异质性和接触面积估算不确定性的共同作用。正如Pathak和Kalidindi[34]所讨论的,堆积和凹陷效应、接触半径变化、非理想压头几何形状以及试样表面条件可在塑性变形开始后影响计算出的压痕应变和应力。这些效应给塑性参数的提取带来了不确定性,并进一步支持使用数值框架来正则化屈服后响应。环氧树脂包埋可能对骨组织引入局部力学约束或支撑,尤其是在树脂浸润相邻孔隙的多孔骨小梁区域。然而,这种效应的幅度取决于包埋条件和压痕采样体积。Bushby等[53]表明,水合和PMMA包埋可改变骨测得的压痕模量,同时也证明较大半径的球形压头和较高载荷可增加采样的材料体积并降低对局部近表面效应的敏感性。在本研究中,使用了直径158 μm的球形压头,且压痕定位在骨组织内并远离可见的骨-环氧树脂界面,这预期可减少直接的表面和边界效应。Mittra等[20]进一步报道,环氧树脂刚度的显著变化并未显著影响犬骨小梁的测得弹性模量,尽管硬度受到影响。然而,局部限制或力学支撑 图10. 所提出的分区特异性材料映射方法在基于临床CT的犬(A)肱骨、(B)胫骨和(C)桡骨模型中的应用。代表性截面展示了指定弹性模量的空间变异,较高模量的皮质区域和骨小梁区域使用连续网格表示,而非计算成本高昂的精细骨小梁建模。https://doi.org/10.1371/journal.pone.0361283.g010

PLOS One | https://doi.org/10.1371/journal.pone.0361283 2026年10月23日 20 / 25 由环氧树脂浸润产生的测量不确定度来源,尤其是小梁骨支柱周围,不能完全排除。既往犬骨研究主要集中于皮质骨,通常报告弹性模量,而小梁骨特性和屈服后行为则表征较少。本研究获得的纵向皮质骨干模量(14.80 ± 0.49 GPa)与Lee等人[18](13.41 ± 5.70 GPa)和Autefage等人[54](15.60 ± 2.6 GPa)先前报道的水合犬股骨皮质骨值相当,也落在Luo等人[19]报道的范围(约15–22 GPa)内。尽管本研究得出的弹性模量总体上与已报道的水合值相当,但这种一致性仍可能受到标本特异性因素的影响,包括骨质量密度和解剖区域。然而,已知水合状态会影响骨刚度;例如,Lee等人[55]报道干燥犬股骨皮质骨的弹性模量约为22–25 GPa,而湿态条件下约为13–15 GPa。本研究在干燥条件下获得的模量相对较低,可能反映了压痕几何形状、标本制备和应力–应变分析的差异。因此,与文献值的比较应结合这些方法学差异来解读。因此,上述研究为水合犬股骨皮质骨的弹性模量建立了有用的参考范围;然而,其范围主要限于弹性表征,而非完整的弹塑性应力–应变测定。此外,Luo等人[19]将小梁骨测量确定为主要局限性,强调完全表征皮质骨和小梁骨两部分的困难。Lin等人[56]报道的犬股骨皮质骨模量值(25.7 GPa)与Mittra等人[20]报道的干燥犬股骨小梁骨模量值(12.97 ± 4.15 GPa)之间的差异,可能部分由解剖部位、标本状态、压头几何形状和分析方法的差异来解释,尤其是当模量从卸载响应中提取时。尽管低于Mittra等人[20]报道的值,本研究干燥标本获得的小梁骨模量具有相似的量级。总体而言,这些比较表明本研究获得的皮质骨弹性模量与已报道的水合犬骨值一致,而本研究通过纳入小梁骨区域并推导弹塑性参数扩展了先前的研究。如前所述,逆向识别框架的优势对屈服后响应尤为重要。压痕衍生的应力–应变曲线提供了弹性模量和表观屈服点的初步估计;然而,在屈服后其直接解读变得越来越不确定,因为塑性变形改变了不断演化的接触几何形状。因此,基于GA的逆向优化程序利用实验载荷–深度响应来细化本构参数,并在校准的压痕范围内识别中间和终端硬化点。这提供了完整的弹塑性材料描述,而无需规定任意的屈服后硬化响应。重复性评估进一步表明,初始屈服参数和终端硬化应力在独立的GA运行中一致识别,而中间硬化点的约束较松。这表明主要本构参数具有良好的稳健性,尽管中间硬化描述仍存在一些非唯一性。该框架的另一个关键优势是减少了在宏观骨有限元分析中显式建模小梁骨微结构的需要。通过推导基于密度的弹塑性材料图,可以纳入小梁骨的有效连续体响应,而无需从μQCT数据进行复杂重建或计算昂贵的小梁骨网格划分。这对于从临床图像衍生的患者特异性有限元分析尤为重要,其中快速模型生成、计算效率和数值稳定性至关重要。所得材料图可支持对损伤起始、骨折风险和承载能力进行更高保真度的估计。用于拟合所建立的E–ρ_app关系的幂律模型E=αρ^β_app与先前犬骨研究中报道的公式一致[25,57]。然而,由于已报道的模量–密度关系随解剖部位、密度定义和测试方法而变化,本研究的关系应在本研究考察的解剖和实验条件范围内解读[25,58]。在未来的研究中,这些关系还可适用于退化骨条件,此类

PLOS One | https://doi.org/10.1371/journal.pone.0361283 2026年10月23日 21 / 25,如骨肉瘤相关骨丢失或骨质疏松症,前提是纳入适当的密度和病理特异性校正因子。图9和图10展示了所提出的材料映射框架在全骨连续体有限元分析(FEA)模型中的应用,其中小梁微架构通过均质化材料属性而非显式小梁几何结构来表示。所得模型包含约一百万个四面体单元,单元尺寸为0.8–1.0 mm。显式解析单个小梁架构的高分辨率FEA模型需要显著更精细的离散化和数百万个单元。例如,Van Rietbergen等[59]报告犬近端股骨约需760万个单元,而人类和小鼠局部骨区域报告约需200万至2100万个单元[60,61]。这一比较说明了在全骨FEA研究中通过连续体尺度均质化属性来表示小梁骨而非显式解析单个小梁的计算优势。尽管本研究的动机是犬长骨弹塑性材料数据有限,但所提出的框架并不局限于单一物种、解剖部位或骨类型。相同的方法学工作流程可适用于其他骨骼、物种、年龄组或病理状况,前提是具备合适的影像学和实验数据。在此背景下,犬股骨是作为该框架的代表性应用而呈现的,而非其更广泛应用的局限。对肱骨、胫骨和桡骨的应用展示了如何在全骨模型中实施隔室特异性连续体材料映射而无需显式解析小梁微架构,从而保持适合非线性全骨FEA的计算规模。作为概念验证研究,本框架是使用选定的解剖区域和单一犬股骨开发的。小梁表征集中于股骨头和远端干骺端,这些区域具有足够显著的小梁架构可供纳米压痕使用。此外,代表性体积单元(RVE)的选择旨在代表区域小梁架构,而非与单个压痕位点空间共定位;因此,局部组织属性与特定RVE架构之间未建立直接的一一对应关系。均质化程序通过有效刚度张量捕捉了架构依赖的弹性响应,而渐进性小梁屈服和载荷重分布则在连续体层面通过随后的屈服及屈服后参数的E依赖性插值纳入,而非显式均质化。由于本研究基于单一股骨,观察到的区域差异应解释为标本内变异。未来需要纳入更多小梁区域、更大且特征明确的队列以及更全面的方向性测试的研究,以评估所提出材料关系的普适性,并进一步将该框架发展为完全正交各向异性弹塑性表征。5. 结论 临床和临床前评估日益依赖有限元分析(FEA)等数值模拟来估计不同条件下的骨承载能力,包括病理病例以及旨在强化骨的生物医学器械的评估。尽管FEA是生物力学中成熟的工具,但其临床和转化应用需要既可靠又计算高效的材料建模策略。本研究提出的框架通过将组织尺度力学属性转化为可直接用于全骨宏观尺度FEA模型的连续体尺度材料输入,满足了这一需求。这对犬长骨尤为重要,因为文献仍缺乏足够的实验衍生材料数据供兽医FEA应用使用,尽管同一概念也可扩展至其他物种,包括人类。许多基于CT的骨模型使用全局值或与灰度强度和密度的经验关系来分配材料属性。然而,这些方法可能忽略区域变异和小梁微架构的力学影响。所提出的框架通过将均质化小梁属性纳入连续体尺度材料映射来弥补这一空白,使全骨FEA模型能够考虑小梁架构而无需

PLOS One | https://doi.org/10.1371/journal.pone.0361283 2026年10月23日 22 / 25 对每个骨小梁进行显式建模。该策略为异质性骨模拟提供了更实用且更具力学代表性的材料输入。尽管球形纳米压痕引入了若干挑战,尤其是对屈服后应力-应变行为解读的噪声问题,但所提出的基于遗传算法的逆向优化框架为提取更稳定且力学一致的弹塑性属性提供了一种实用解决方案。这一点尤为重要,因为屈服后行为在预测骨力学中损伤的起始和进展方面起着关键作用。将这些相关性应用于四种不同的犬长骨进一步证明了它们作为实用本构关系的潜力,可将密度与全骨有限元分析中的材料属性联系起来。由于这些关系是从单一犬股骨开发的,因此需要在更多样本中进行进一步验证以评估其普适性,尽管相同流程可以应用。此外,将优化材料图与基于CT的传统材料赋值进行直接比较,将是评估它们对全骨力学预测影响的重要下一步。总体而言,该框架将实验数据的使用扩展到简单的属性报告之外,并为未来的患者个体化生物力学模拟提供了异质性弹塑性材料图。支持信息 S1附录。补充方法和结果。关于球形纳米压痕校准和应力-应变公式、基于遗传算法的逆向优化、从μQCT数据重建RVE及均匀化、实验和优化材料参数的变异性,以及骨小梁RVE均匀化正交各向异性属性的额外细节。(DOCX)S1图。弹塑性参数实验和数值定义的图示。(A)代表性纳米压痕力-位移响应;(B)相应的压痕应力-应变曲线,显示实验估计的初始表观屈服点;(C)逆向优化中使用的三个应力-应变控制点的示意图,其中(σ 0 y ,ε 0 y)表示初始表观屈服点,(σ 1 y ,ε 1 y)是中间硬化控制点,(σ 2 y ,ε 2 y)是校准应变范围内的终止硬化点。(TIF)S2图。代表性皮质样本的实验和优化有限元响应的比较。(A–C)实验和优化有限元力-位移曲线,显示在整个压痕深度上的一致性。(D–F)相应的表观压痕应力-应变响应,以及逆向识别的本构控制点(σ 0 y ,ε 0 y)、(σ 1 y ,ε 1 y)和(σ 2 y ,ε 2 y)。第二和第三控制点是逆向识别的屈服后参数,预计不会直接与表观实验应力-应变响应重合,因为屈服后接触面积估计变得越来越不确定。(TIF)致谢 作者还要感谢俄亥俄州立大学材料科学与工程系的Wayne Papageorge的支持。作者贡献 概念化:Tareq Zobaer、Janis Lapsley、Do-Gyoon Kim、Laura E. Selmic、Ali Nassiri。数据管理:Behzad Amirzade、Tareq Zobaer。形式分析:Behzad Amirzade、Tareq Zobaer、Laura E. Selmic、Ali Nassiri。

PLOS One | https://doi.org/10.1371/journal.pone.0361283 2026年10月23日 23 / 25 经费获取:Laura E. Selmic、Ali Nassiri。调查研究:Behzad Amirzade、Tareq Zobaer、Do-Gyoon Kim、Laura E. Selmic、Ali Nassiri。方法学:Behzad Amirzade、Tareq Zobaer、Janis Lapsley、Do-Gyoon Kim、Laura E. Selmic、Ali Nassiri。项目管理:Laura E. Selmic、Ali Nassiri。资源:Laura E. Selmic。软件:Ali Nassiri。监督:Laura E. Selmic、Ali Nassiri。验证:Behzad Amirzade、Janis Lapsley、Do-Gyoon Kim、Laura E. Selmic、Ali Nassiri。可视化:Behzad Amirzade、Tareq Zobaer。写作——初稿:Behzad Amirzade、Tareq Zobaer。写作——审阅与编辑:Janis Lapsley、Do-Gyoon Kim、Laura E. Selmic、Ali Nassiri。参考文献 1. Ibrahim A, Magliulo N, Groben J, Padilla A, Akbik F, Abdel Hamid Z. 硬度——骨质量的重要指标,以及胶原蛋白在骨硬度中的作用。J Funct Biomater. 2020;11(4):85. https://doi.org/10.3390/jfb11040085 PMID: 33271801 2. Managuli V, Bothra YS, S SK, Gaur P, Ch PL, Racharya. 使用纳米压痕技术进行骨力学表征及其应用概述。Eng Sci. 2023;22:820。 3. Endo D, Ogami-Takamura K, Imamura T, Saiki K, Murai K, Okamoto K, 等. 基于CT的有限元方法分析显示,皮质骨厚度减少会增加女性股骨骨干的应力和应变:对股骨疲劳性骨折解剖学背景的意义。Bone Rep. 2020;13:100733. https://doi.org/10.1016/j.bonr.2020.100733 PMID: 33294500 4. Saillard E, Gardegaront M, Levillain A, Bermond F, Mitton D, Pialat J-B, 等. 用于失效载荷计算的自动计算机断层扫描骨分割有限元模型。Sci Rep. 2024;14(1):16576. https://doi.org/10.1038/s41598-024-66934-w PMID: 39019937 5. Sas A, Tanck E, Sermon A, van Lenthe GH. 用于转移性骨病患者骨折预防的有限元模型。文献综述。Bone Rep. 2020;12:100286. https://doi.org/10.1016/j.bonr.2020.100286 PMID: 32551337 6. Soltani Z, Xu M, Radovitzky R, Stadelmann MA, Hackney D, Alkalay RN. 基于CT的有限元模拟空间骨损伤累积可预测转移性人椎体的强度和刚度。Front Bioeng Biotechnol. 2024;12:1424553. https://doi.org/10.3389/fbioe.2024.1424553 PMID: 39108596 7. Hernández-Salazar CA, Chamorro CE, González-Estrada OA. 结合放射组学技术和有限元分析表征轴向压缩下猪椎体。Inventions. 2024;9(2):36. https://doi.org/10.3390/inventions9020036 8. Sadighi A, Taheri M, Black N, Stolle J, Taghvaei M, Boyes M, 等. 考虑异质特性的膨胀锚钉诱导骨重塑的有限元分析。Biomech Model Mechanobiol. 2025;24(6):1937–58. https://doi.org/10.1007/s10237-025-02001-1 PMID: 40817952 9. Pervez Y, Stiles C, Yang Z, Pageau A, Ying J, Davidson J, 等. 模拟尸体肩峰加载有限元模型中图像重建核与密度-模量关系的影响。J Biomech. 2025;190:112876. https://doi.org/10.1016/j.jbiomech.2025.112876 PMID: 40694945 10. An YH, Draughn RA. 骨的力学性能与测试方法。骨科研究中的动物模型。CRC Press;1998。 11. Kim D-G, Huja SS, Lee HR, Tee BC, Hueni S. 通过纳米压痕测量的骨基质粘度与接触硬度和模量的关系。J Biomech Eng. 2010;132(2):024502. https://doi.org/10.1115/1.4000936 PMID: 20370248 12. Kommidi SR, Kim Y-R, Kim D-G. 大鼠骨粘弹性变形与速率依赖性断裂损伤的建模。Int J Damage Mech. 2024;34(6):920–43. https://doi.org/10.1177/10567895241245716 13. Cyganik Ł, Binkowski M, Kokot G, Rusin T, Popik P, Bolechała F, 等. 利用宏观尺度的骨密度与力学性能关系预测微观尺度骨小梁的杨氏模量。J Mech Behav Biomed Mater. 2014;36:120–34. https://doi.org/10.1016/j.jmbbm.2014.04.011 PMID: 24837330 14. Pawlikowski M, Skalski K, Bańczerowski J, Makuch A, Jankowski K. 基于深度传感压痕测量的人骨小梁应力-应变特征。Biocybern Biomed Eng. 2017;37:272–80. https://doi.org/10.1016/j.bbe.2017.01.002 15. Rho JY, Roy ME 2nd, Tsui TY, Pharr GM. 通过纳米压痕测量的人骨组织微结构组分的弹性性能。J Biomed Mater Res. 1999;45(1):48–54. https://doi.org/10.1002/(sici)1097-4636(199904)45:1<48::aid-jbm7>3.0.co;2-5 PMID: 10397957 16. Rho JY, Tsui TY, Pharr GM. 通过纳米压痕测量的人皮质骨和骨小梁板层骨的弹性性能。Biomaterials. 1997;18(20):1325–30. https://doi.org/10.1016/s0142-9612(97)00073-2 PMID: 9363331

PLOS One | https://doi.org/10.1371/journal.pone.0361283 2026年10月23日 24 / 25 17. Jiroušek O, Němeček J, Kytýř D, Kunecký J. 骨小梁的纳米压痕——与单根骨小梁单轴试验的比较。Chem Listy。2011。18. Lee K-L, Sobieraj M, Baldassarri M, Gupta N, Pinisetty D, Janal MN, 等。加载条件和试样环境对犬皮质骨纳米力学响应的影响。Mater Sci Eng C Mater Biol Appl。2013;33(8):4582–6。https://doi.org/10.1016/j.msec.2013.07.018 PMID: 24094163 19. Luo C, Liao J, Zhu Z, Wang X, Lin X, Huang W. 不同年龄犬骨组织力学性能和力学各向异性的分析。Biomed Res Int。2019;2019:3503152。https://doi.org/10.1155/2019/3503152 PMID: 31341896 20. Mittra E, Akella S, Qin Y-X. 包埋材料、加载速率与大小以及压入深度对骨小梁纳米压痕的影响。J Biomed Mater Res A。2006;79(1):86–93。https://doi.org/10.1002/jbm.a.30742 PMID: 16758456 21. Pressel T, Bouguecha A, Vogt U, Meyer-Lindenberg A, Behrens B-A, Nolte I, 等。犬股骨骨小梁的力学性能。Biomed Eng Online。2005;4:17。https://doi.org/10.1186/1475-925X-4-17 PMID: 15774014 22. Turner CH, Rho J, Takano Y, Tsui TY, Pharr GM. 骨小梁和皮质骨组织的弹性性能相似:两种显微测量技术的结果。J Biomech。1999;32(4):437–41。https://doi.org/10.1016/s0021-9290(98)00177-8 PMID: 10213035 23. Bhandal J, Boston SE. 疑似或确诊骨肉瘤犬的病理性骨折。Vet Surg。2011;40(4):423–30。https://doi.org/10.1111/j.1532-950X.2011.00811.x PMID: 21395621 24. Pope EA, Wavreille VA, Lapsley JL, Green EM, Kisseberth WC, Rabiner R. 在六只疑似附肢骨肉瘤犬中,立体定向体部放疗后使用IlluminOss光动力骨稳定系统进行保肢。Vet Comp Oncol。2026(vco.70082)。https://doi.org/10.1111/vco.70082 25. Kuhn JL, Goldstein SA, Ciarelli MJ, Matthews LS. 犬骨小梁作为人类模型的局限性:一项生物力学研究。J Biomech。1989;22(2):95–107。https://doi.org/10.1016/0021-9290(89)90032-8 PMID: 2708399 26. Choi K, Khang G, Goldstein SA. 犬骨小梁组织的弹性模量和疲劳性能。KSME Int J。2001;15(7):1022–31。https://doi.org/10.1007/bf03185280 27. Pathak S, Vachhani SJ, Jepsen KJ, Goldman HM, Kalidindi SR. 利用新型球形纳米压痕数据分析方法评估小鼠骨的板层水平性能。J Mech Behav Biomed Mater。2012;13:102–17。https://doi.org/10.1016/j.jmbbm.2012.03.018 PMID: 22842281 28. Hertz H. 论刚性弹性固体的接触与硬度。Misc Pap。1896。pp. 163–83。29. Oliver WC, Pharr GM. 一种利用载荷和位移传感压痕实验测定硬度和弹性模量的改进技术。J Mater Res。1992;7:1564–83。https://doi.org/10.1557/JMR.1992.1564 30. Chen Z, Diebels S. 粘弹性聚合物层纳米压痕问题中的参数再识别:小变形。Z Angew Math Mech。2012;93(2–3):88–101。https://doi.org/10.1002/zamm.201100170 31. Kontomaris SV, Stylianou A, Nikita KS, Malamou A. 关于在AFM纳米压痕实验中对生物样品应用赫兹接触理论的讨论。Micro Nanosyst。2021;13(1):42–8。https://doi.org/10.2174/1876402912666200115160207 32. Poon B, Rittel D, Ravichandran G. 线弹性固体中纳米压痕的分析。Int J Solids Struct。2008;45(24):6018–33。https://doi.org/10.1016/j.ijsolstr.2008.07.021 33. Remache D, Semaan M, Rossi JM, Pithioux M, Milan JL. Johnson-Cook塑性模型在皮质骨纳米压痕有限元模拟中的应用。J Mech Behav Biomed Mater。2020;101:103426。https://doi.org/10.1016/j.jmbbm.2019.103426 PMID: 31557661 34. Pathak S, Kalidindi SR. 球形纳米压痕应力-应变曲线。Mater Sci Eng R Rep。2015;91:1–36。https://doi.org/10.1016/j.mser.2015.02.001 35. Yan C, Geers MGD, Giuntini D. 从球形纳米压痕提取流动曲线:超晶纳米复合材料案例。Mater Des。2025;259:114903。https://doi.org/10.1016/j.matdes.2025.114903 36. Guha I, Zhang X, Rajapakse CS, Chang G, Saha PK. 利用CT成像和连续介质力学建模对骨小梁微结构进行有限元分析。Med Phys。2022;49(6):3886–99。https://doi.org/10.1002/mp.15629 PMID: 35319784 37. Donnelly E, Baker SP, Boskey AL, van der Meulen MCH. 表面粗糙度和最大载荷对纳米压痕测量松质骨力学性能的影响。J Biomed Mater Res A。2006;77(2):426–35。https://doi.org/10.1002/jbm.a.30633 PMID: 16392128 38. Pepe V, Oliviero S, Cristofolini L, Dall'Ara E. C57BL/6和Balb/C雌性小鼠胫骨不同位置的区域纳米压痕性能。Front Bioeng Biotechnol。2020;8:478。https://doi.org/10.3389/fbioe.2020.00478 PMID: 32500069 39. MTS Systems Corporation. 用于纳米压痕系统的TestWorks 4软件。Oak Ridge, Tennessee, USA: MTS Systems Corporation; 2002。40. Kim D-G, Jeong Y-H, Kosel E, Agnew AM, McComb DW, Bodnyk K, 等。人下颌骨髁突骨组织性能的区域变异。Bone。2015;77:98–106。https://doi.org/10.1016/j.bone.2015.04.024 PMID: 25913634 41. Li X, Bhushan B. 纳米压痕连续刚度测量技术及其应用综述。Mater Charact。2002;48:11–36。https://doi.org/10.1016/S1044-5803(02)00192-4 42. Cheng Y-T, Cheng C-M. 能否利用锥形和棱锥形压头从压痕曲线获得应力-应变关系?J Mater Res。1999;14(9):3493–6。https://doi.org/10.1557/jmr.1999.0472

PLOS One | https://doi.org/10.1371/journal.pone.0361283 2026年10月23日 25 / 25 43. Juliano TF, Vanlandingham MR, Weerasooriya T, Moy P. 从球形压痕中提取应力-应变与压缩屈服应力信息. 2007 [引用日期 2026年4月27日]. 可获取于: https://apps.dtic.mil/sti/html/tr/ADA472755/ 44. Francis HA. 塑性球形压痕的现象学分析. J Eng Mater Technol. 1976;98:272–81. https://doi.org/10.1115/1.3443378 45. Nesbitt DQ, Nelson ML, Shannon KS, Lujan TJ. Dots-on-plots:用于分析软组织拉伸试验应力-应变曲线的网络应用程序. J Biomech Eng. 2022;145. https://doi.org/10.1115/1.4055593 46. Dassault Systèmes Simulia Corp. ABAQUS. 美国罗德岛州普罗维登斯:Dassault Systèmes;2024. 可获取于: https://discover.3ds.com/ 47. The MathWorks, Inc. MATLAB. 美国马萨诸塞州纳蒂克:The MathWorks Inc.;2024. 可获取于: https://www.mathworks.com 48. Asgari M, Abi-Rafeh J, Hendy GN, Pasini D. 通过原子力显微镜压痕研究成年小鼠股骨皮质骨与松质骨的材料各向异性与弹性. J Mech Behav Biomed Mater. 2019;93:81–92. https://doi.org/10.1016/j.jmbbm.2019.01.024 PMID: 30776678 49. Aitkenhead A. 网格体素化. MATLAB Central File Exchange;2026. 可获取于: https://www.mathworks.com/matlabcentral/fileexchange/27390-mesh-voxelisation 50. Zobaer SMT, Sutradhar A. 一种基于能量的方法:通过参数化建模实现不相容微结构的界面连接. Comput Methods Appl Mech Eng. 2020;370:113278. https://doi.org/10.1016/j.cma.2020.113278 51. Dong G, Tang Y, Zhao YF. 一个用MATLAB编写的149行三维多孔材料均匀化代码. J Eng Mater Technol. 2018;141. https://doi.org/10.1115/1.4040555 52. Helgason B, Gilchrist S, Ariza O, Vogt P, Enns-Bray W, Widmer RP, 等. 模量-密度关系与材料映射方法对侧向跌倒加载构型下近端股骨模拟力学响应的影响. Med Eng Phys. 2016;38(7):679–89. https://doi.org/10.1016/j.medengphy.2016.03.006 PMID: 27185044 53. Bushby AJ, Ferguson VL, Boyde A. 骨的纳米压痕:液体中测试标本与包埋于聚甲基丙烯酸甲酯中标本的比较. J Mater Res. 2004;19:24. https://doi.org/10.1557/jmr.2004.19.1.249 54. Autefage A, Palierne S, Charron C, Swider P. 犬股骨骨干皮质骨的有效力学性能. Vet J. 2012;194(2):202–9. https://doi.org/10.1016/j.tvjl.2012.04.001 PMID: 22595311 55. Lee K-L, Baldassarri M, Gupta N, Pinisetty D, Janal MN, Tovar N, 等. 犬股骨骨在干燥与湿润条件下准静态范围内应变率敏感性的纳米力学表征. Int J Biomater. 2012;2012:415230. https://doi.org/10.1155/2012/415230 PMID: 23365577 56. Lin ZX, Xu Z-H, An YH, Li X. 犬皮质骨弯曲下断裂行为的原位观察. Mater Sci Eng C Mater Biol Appl. 2016;62:361–7. https://doi.org/10.1016/j.msec.2016.01.061 PMID: 26952434 57. Brekhus C, Labus K, Seguin B, Puttlitz C, Gadomski B. 用于犬骨肉瘤模型骨折风险预测的患者特异性有限元建模. Ann Transl Med. 2024;12:5. https://doi.org/10.21037/atm-23-1699 58. Kang Q, An YH, Friedman RF. 犬松质骨的力学性能与骨密度. J Mater Sci Mater Med. 1998;9(5):263–7. https://doi.org/10.1023/a:1008852610820 PMID: 15348882 59. Van Rietbergen B, Müller R, Ulrich D, Rüegsegger P, Huiskes R. 犬近端股骨骨小梁的组织应力与应变可通过计算机重建进行量化. J Biomech. 1999;32(4):443–51. https://doi.org/10.1016/s0021-9290(99)00024-x PMID: 10213036 60. Farage-O’Reilly SM, Cheong VS, Pickering E, Pivonka P, Bellantuono I, Kadirkamanathan V, 等. 加载方向显著影响小鼠胫骨的力学性能. Front Bioeng Biotechnol. 2024;12:1335955. https://doi.org/10.3389/fbioe.2024.1335955 PMID: 38380263 61. Sadoughi S, Bevill G, Morgan EF, Palepu V, Keaveny TM, Wear KA. 人松质骨的生物力学结构-功能关系——跟骨、股骨颈、大转子、近端胫骨与椎骨的比较. Comput Methods Biomech Biomed Engin. 2023;26:508–16. https://doi.org/10.1080/10255842.2022.2069465

查看英文原文▾

PLOS One | https://doi.org/10.1371/journal.pone.0361283 October 23, 2026 1 / 25

OPEN ACCESS Citation: Amirzade B, Zobaer T, Lapsley J, Kim D-G, Selmic LE, Nassiri A (2026) An integrated experimental–computational framework for elasto-plastic characterization and spatial mapping of canine bone properties. PLoS One 21(10): e0361283. https://doi.org/10.1371/ journal.pone.0361283 Editor: Alice Berardo, University of Padova: Universita degli Studi di Padova, ITALY Received: June 11, 2026 Accepted: October 8, 2026 Published: October 23, 2026 Copyright: © 2026 Amirzade et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. Data availability statement: This paper contains all raw data required to replicate the results of the study. This includes the minimum dataset necessary to reproduce all findings reported in the article, as well as the written code, relevant metadata, and methodological RESEARCH ARTICLE An integrated experimental–computational framework for elasto-plastic characterization and spatial mapping of canine bone properties Behzad Amirzade 1,2 , Tareq Zobaer 1,2 , Janis Lapsley 3 , Do-Gyoon Kim 4 , Laura E. Selmic 3 , Ali Nassiri 1,2 * 1 Department of Integrated Systems Engineering, College of Engineering, The Ohio State University, Columbus, Ohio, United States of America, 2 Simulation Innovation and Modeling Center, The Ohio State University, Columbus, Ohio, United States of America, 3 Department of Veterinary Clinical Sciences, College of Veterinary Medicine, The Ohio State University, Columbus, Ohio, United States of America, 4 Division of Orthodontics, College of Dentistry, The Ohio State University, Columbus, Ohio, United States of America * nassiri.3@osu.edu Abstract Bone is a hierarchical and heterogeneous bio-composite material, with cortical and trabecular regions exhibiting distinct mechanical behaviors across scales. Patient- specific Finite Element Analysis (FEA) derived from medical images is increasingly used in both human and veterinary medicine to predict bone mechanical behavior under various loading conditions, assess fracture risk, and evaluate treatment outcomes. However, due to the complexity associated with measuring full elasto-plastic bone properties across multiple scales and bridging microscale properties to macroscale models, simplified material definitions are often adopted in FEA simulations. Such simplifications may produce unrealistic mechanical responses and fail to capture permanent microscopic and macroscopic deformations that occur when stresses exceed the bone yield point, particularly in implant design applications. This study presents an integrated experimental–computational framework for generating continuum material maps as a function of density from tissue-scale characterization of the canine femur. High-depth spherical nanoindentation combined with Genetic Algorithm (GA)-based inverse optimization was conducted to extract mechanically consistent elasto-plastic properties of cortical and trabecular bone from load–displacement responses influenced by post-yield contact uncertainties. Trabecular tissue-scale properties were then assigned to Representative Volume Elements (RVEs) reconstructed from micro-Quantitative Computed Tomography (μQCT) data and homogenized to account for architecture-dependent effective behavior. Finally, optimized cortical and homogenized trabecular properties were correlated with density to establish compartment-specific material mapping relationships for whole-bone FEA simulations. The optimized responses showed good agreement with the experimental indentation measurements, supporting the capability of the proposed framework to generate

PLOS One | https://doi.org/10.1371/journal.pone.0361283 October 23, 2026 2 / 25 mechanically informed material definitions for patient-specific bone FEA simulations. Overall, the proposed framework provides a pathway for translating localized experimental measurements into heterogeneous elasto-plastic material inputs for wholebone FEA without explicitly resolving trabecular microarchitecture. 1. Introduction Bone is a hierarchical and heterogeneous material composed of organic and mineral phases, with cortical and trabecular compartments showing distinct density, architecture, and mechanical behavior [1,2]. Accurate characterization of these compartments is essential for developing reliable constitutive models for Finite Element Analysis (FEA), particularly for predicting bone deformation and fracture. This is clinically important because reconstruction from medical images is increasingly used to generate patient-specific bone models for FEA, supporting fracture-risk assessment, treatment evaluation and planning, and rapid clinical triage. Recent studies have utilized Computed Tomography (CT) and micro-Quantitative Computed Tomography (μQCT) images to generate subject-specific FEA models of bone for estimating damage and fracture risk [3–6]. In these models, heterogeneous material properties are commonly assigned using relationships between Hounsfield Unit (HU), bone mass density, and elastic modulus, especially for clinical CT-derived FEA. Other studies have also used HU-dependent material mapping to represent spatial variation in bone stiffness and improve anatomical realism in FEA simulations [6–8]. However, the accuracy of these models strongly depends on the selected modulus–density relationship. Pervez et al. [9] showed that different modulus–density equations can substantially affect FEA predictions, particularly when the relationships are not bone-specific or do not distinguish between cortical and trabecular compartments. In addition, many bone FEA studies rely on empirical modulus–density equations from the literature rather than relationships derived from the actual local bone architecture of the modeled specimen. Therefore, current knowledge supports the importance of heterogeneous CT-based material mapping, but also shows that stronger links are needed between experimentally measured tissue properties and compartment-specific material assignment for high-fidelity whole-bone FEA. Mechanical properties of bone can be measured at different scales, from macroscale compression, tension or bending tests that capture bulk response to nanoindentation methods that characterize local tissue-level elastic and plastic behavior [10–12]. Although nanoindentation characterization of human bone has been widely reported under both wet and dry conditions [13–16], site-specific elasto-plastic properties of canine bone, especially beyond elastic modulus and hardness, remain limited. Canine bone studies have mainly focused on limited regions such as the femoral head, distal metaphysis, or cortical diaphysis [17–22]. This limitation is particularly relevant in veterinary applications, where accurate material properties are needed to assess bone strength and fracture risk in conditions such as osteosarcoma [23,24]. Canine bone is also widely used in musculoskeletal research; however, details. All data and supporting materials have been deposited in Zenodo and can be accessed through the following link: https://doi. org/10.5281/zenodo.22713213. Funding: Funding from Morris Animal Foundation (Grant # D22CA-511) is gratefully acknowledged. The funders had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript. Competing interests: The authors have declared that no competing interests exist.

PLOS One | https://doi.org/10.1371/journal.pone.0361283 October 23, 2026 3 / 25 species-specific differences remain important, as canine trabecular bone has been reported to exhibit lower elastic modulus and fatigue strength than human trabecular bone [25,26]. Many previous bone nanoindentation studies have used Berkovich tips, mainly on human or other non-canine species, to obtain elastic modulus rather than full stress–strain or post-yield behavior. Spherical indenters provide a larger initial elastic regime and a smoother, progressively evolving contact stress field, allowing the mechanical response to be followed from elasticity through yielding and into post-yield behavior [27]. Their rounded geometry can also reduce stress concentrations and the likelihood of premature cracking or sudden fracture during indentation of brittle or fracture-sensitive materials. Thus, limited information is currently available on site-specific elasto-plastic properties of canine long bone obtained through spherical nanoindentation, although such properties are important for accurate FEA modeling. Despite the wide use of Hertzian and Oliver–Pharr indentation analysis [28,29], converting spherical nanoindentation load–displacement data into reliable stress–strain curves remains challenging for biological tissues. Bone violates many of the assumptions underlying these analytical models because it is heterogeneous, anisotropic, porous, and may exhibit non-fully elastic unloading behavior [30–33]. In addition, the complex and nonuniform elastic–plastic stress field beneath a spherical indenter makes direct conversion of indentation data into representative stress–strain curves non-trivial [34,35]. Therefore, a numerical analysis framework is required to regularize the interpretation of nanoindentation data by matching the experimental load–displacement response with FEA predictions and extracting more reliable elasto-plastic material properties. Moreover, accurate material assignment remains a major challenge in FEA models derived from CT images. In patient-specific whole-bone simulations, the image resolution is usually insufficient to resolve the individual trabeculae matrix and local microstructural connectivity of trabecular bone. Guha et al. [36] demonstrated that continuum FEA implemented directly on a CT voxel grid can estimate trabecular bone modulus by assigning density-based material properties to CT voxels, thereby avoiding explicit segmentation of trabecular architecture. However, their approach required an optimized mesh size of 100 μm. Although this resolution is practical for a small trabecular Region of Interest (ROI), its application to whole long-bone models (e.g., with lengths of 200–300 mm) would result in a prohibitively large number of elements on the order of million elements and substantially increased computational cost, limiting its scalability for patient-specific analysis of entire bones. Therefore, although high-resolution continuum FEA constructed directly from CT voxels is useful for localized trabecular modulus estimation, directly applying such fine voxel or mesh resolution to patient-specific whole-bone fracture simulations remains impractical. This creates a need for a micro-to-continuum material mapping approach that homogenizes microscale properties and microstructural effects into mechanically meaningful continuum-level properties suitable for clinical-scale canine long-bone FEA. This study aims to propose a systematic pathway that: I) experimentally characterize the microscale elasto-plastic response of both trabecular and cortical regions of canine long bone, specifically the femur of a large-breed dog, using spherical nanoindentation across different anatomical sites; II) develop a Genetic Algorithm (GA)-based inverse optimization framework to improve the extraction of stress–strain behavior from force–displacement data by linking the experimental response with replicated FEA indentation simulations; and III) translate the optimized microscale properties to the continuum scale through trabecular bone homogenization and the development of compartment-specific modulus–density relationships for canine long bone. Together, these objectives support high-fidelity elasto-plastic material assignment for clinical CT-derived FEA models, where trabecular microstructure cannot be explicitly captured in detail, and provide physically relevant material inputs for fracture-risk assessment and biomechanical simulation. The novelty of this work lies in integrating these experimental and computational steps into a unified framework that translates localized nanoindentation measurements into spatially varying material-property maps for whole-bone FEA, as illustrated in Fig 1. The remainder of this paper is organized as follows. First, the nanoindentation experimental setup and testing procedure for microscale characterization of trabecular and cortical bone are described, followed by the extraction of elasto-plastic properties from the nanoindentation results. Next, the material mapping framework is presented, including

PLOS One | https://doi.org/10.1371/journal.pone.0361283 October 23, 2026 4 / 25 the homogenization scheme used to obtain effective trabecular properties and the development of modulus–density correlations for canine long bone. The experimental results, numerical optimization outcomes, and material maps are then presented and discussed. Finally, the main conclusions and future implications of the study are summarized. 2. Methodology 2.1. Experimental setup and procedure Bone specimens were obtained in dry condition from the femur of a large-breed dog provided by the Department of Veterinary Clinical Sciences at The Ohio State University. Six specimens were sectioned at different locations using a Leco VC-50 precision saw with a diamond cut-off wheel. The sections were cold-mounted in a two-part Leco epoxy resin (Leco Epoxy Resin and Hardener at a 100:14 mass ratio) under vacuum to promote resin infiltration into the porous bone structure and enhance specimen stability during preparation and indentation. Complete epoxy support around the base of each trabecula is important to minimize mechanical artifacts; incomplete embedding may allow a trabecula to deform as a cantilevered beam during indentation, potentially leading to inaccurate measurements of its mechanical properties. After curing for 8–12 hours at room temperature, the mounted samples were ground and polished using a Buehler EcoMet 3000 semi-automatic grinder/polisher. Grinding was performed sequentially with 600, 800, and 1200 grit silicon carbide papers, followed by polishing with 3 μm diamond paste and 0.05 μm colloidal silica. Between each step, the samples were cleaned with water and reagent-grade ethanol and dried to minimize surface contamination and polishing artifacts. These preparation steps were used to progressively reduce surface defects and surface roughness and to improve the consistency and reliability of the nanoindentation measurements, consistent with preparation approaches reported in previous bone nanoindentation studies [37,38]. Representative mounted samples and optical microscopy images of the prepared cross-sections are shown in Fig 2. Microscopic images were acquired at 100 × magnification using an Olympus GX53 inverted optical microscope in brightfield (BF) mode with PAXcam software. Fig 1. Overview of the proposed integrated experimental-numerical framework. The workflow includes material characterization using spherical nanoindentation; data extraction and post-processing using GA-based inverse identification of elasto-plastic parameters; material realization of microstructure using RVE homogenization; and elasto-plastic material mapping. https://doi.org/10.1371/journal.pone.0361283.g001

PLOS One | https://doi.org/10.1371/journal.pone.0361283 October 23, 2026 5 / 25 Spherical nanoindentation tests were conducted using an MTS Nano-XP nanoindenter equipped with a sapphire spherical tip with a diameter of 158 μm, an elastic modulus of 345 GPa, and a Poisson’s ratio of 0.29. The standard Nano-XP system has a maximum normal load capacity of 500 mN, a theoretical force resolution of 50 nN, and a displacement resolution of <0.1 nm [39]. The indentation sites were selected using the built-in optical microscope to ensure that the indents were placed within the target bone regions and away from visible defects or the bone–epoxy interface. To minimize potential local boundary and confinement effects, indentation locations were selected primarily based on surface quality, targeting clean, smooth, and visually intact regions. No additional anatomical or mechanical selection criteria were applied. A custom bone indentation protocol was applied under displacement control, with maximum indentation depths of 4000 nm for trabecular bone and 5000 nm for cortical bone. The protocol was described by Kim et al. [40]. Additional Fig 2. Embedded bone samples in epoxy and the corresponding optical micrographs. Sections a–f were taken from the (a) femoral head, (b) proximal metaphysis, (c) diaphysis – L, (d) diaphysis – T, (e) diaphysis – R, and (f) distal metaphysis. L, T, and R denote longitudinal (parallel to the femoral axis), tangential, and radial directions, respectively. Dashed lines indicate approximate sectioning locations and orientations. Section (a) was obtained at θ ≈ 38°. Red boxes indicate the approximate regions used for optical imaging and nanoindentation. The specimen diameter (d s ) was approximately 35 mm. Here, φ denotes the femoral shaft diameter, and the φ/2 offset indicates the near-surface section used to enable radial indentation. Scale bars represent 250 μm. https://doi.org/10.1371/journal.pone.0361283.g002

PLOS One | https://doi.org/10.1371/journal.pone.0361283 October 23, 2026 6 / 25 testing parameters included an allowable drift rate of 0.2 nm/s, surface approach distance of 1000 nm, surface approach velocity of 10 nm/s, and settling time of 25 s. Before testing, the indenter tip was calibrated using fused silica [16]. All tests were performed using the continuous stiffness measurement technique. In this technique, a small oscillatory signal is superimposed on the applied load to continuously determine contact stiffness as a function of indentation depth. At each depth, hardness is calculated from the applied load and projected contact area, while the elastic modulus is derived from the measured contact stiffness and contact area, accounting for the elastic properties of the indenter. This approach enables depth-dependent measurement of mechanical properties and is particularly suitable for heterogeneous materials such as bone [41]. Ethics statement. The specimen used in this study was provided by The Ohio State University College of Veterinary Medicine, where standard written owner consent is obtained before treatment as part of the routine clinical consent process. 2.2. Elasto-plastic data extraction Instrumented spherical nanoindentation was used to characterize the local elasto-plastic response of canine bone tissue. The initial elastic response of the spherical nanoindentation load–displacement curve was interpreted using Hertzian contact theory [28], which relates the applied load (P), indentation depth (h t ), tip radius (R), and reduced elastic modulus (E * ) under purely elastic contact conditions, as shown in Fig 3A. The reduced modulus of the sample was introduced to account for the material properties of both the indenter and the specimen:

E ∗ = [ 1–ν 2 E + 1–ν i 2 E i ] –1 (1) where E and ν are the elastic modulus and Poisson’s ratio of the sample, respectively, while E i = 345 GPa and ν i = 0.29 are the corresponding properties of the indenter. Once the tip is calibrated, E * can be found using contact depth (h c ) and h t , as detailed in S1 Appendix (see Section S1.1). The representative spherical indentation marks on the trabecular and cortical microstructure are also shown in Fig 3B and 3C, respectively. Spherical indentation differs fundamentally from conical and pyramidal indentation because the spherical tip is geometrically non-self-similar. In self-similar indenters, the contact geometry scales proportionally with penetration depth, whereas in spherical indentation the contact radius, projected contact area, and subsurface stress field evolve continuously and nonlinearly as indentation depth increases [42,43]. This depth-dependent evolution of contact geometry enables Fig 3. Spherical nanoindentation and representative indentation impressions. (A) Schematic of the spherical indenter in contact with the sample, where a is the projected contact radius at maximum load, h c is the contact depth, h t is the total indentation depth, and d is the residual indentation impression diameter measured after unloading; Representative micrographs of the nanoindentation impressions on (B) trabecular bone, and (C) cortical bone samples. Blue circles indicate the residual indentation impressions. https://doi.org/10.1371/journal.pone.0361283.g003

PLOS One | https://doi.org/10.1371/journal.pone.0361283 October 23, 2026 7 / 25 the loading response to be associated with a representative indentation strain. Consequently, the spherical indentation load–displacement curve can be transformed into an indentation stress–strain response, providing a more suitable basis for evaluating the elasto-plastic behavior of bone tissue as a semi-brittle material following the approach proposed by Juliano et al. [43]. The indentation stress was calculated as the applied load divided by the projected contact area:

σ= ψP πa 2 =0.9 ( h t h c –1 ) P πa 2 (2) where a is the projected contact radius and ψ= 0.9(ht/hc–1) is a depth-dependent correction factor. As indentation progresses, ht/hc changes naturally, allowing the correction factor ψ to account for the gradual transition from predominantly elastic contact to elastic-plastic deformation. The factor has been reported to be approximately 0.9 in the purely elastic regime and to decrease as plastic deformation develops [43,44]. After the indentation stress was obtained, the corresponding expression for true strain was calculated using the relationship between indentation stress, elastic modulus, contact geometry, total indentation depth, contact depth, and calibrated projected contact area. The complete derivation and equations used for the indentation strain calculation are provided in Section S1.1 of S1 Appendix. Once the indentation stress and strain were calculated from the experimental nanoindentation data, the elastic modulus and apparent initial yield point were estimated from the resulting curves. The apparent initial yield point was defined as the onset of deviation from the initial linear response. Following the derivative approach described by Nesbitt et al. [45], this point was identified from the early portion of the curve as the location of maximum slope among the zero crossings of the second derivative. The second derivative was used to identify candidate stationary points in the first derivative, where changes in the evolution of the curve slope occur. This criterion identifies the transition in slope from the initial linear response to the nonlinear regime. In this study, the search region was limited to strains below 1.5% to ensure that the identified point corresponded to the initial elastic-to-nonlinear transition rather than later post-yield behavior. Because the experimentally derived indentation stress–strain curves contained local point-by-point oscillations, particularly after yielding, direct numerical differentiation could become unstable as differentiation amplifies local variations in the data. Therefore, a 12th-degree polynomial was fitted to the data to obtain a smooth representation of the response before calculating the first and second derivatives. The elastic modulus was then determined as the slope of a least-square linear fit over a 0.5% strain interval immediately preceding the identified apparent yield point. Beyond the elastic regime, direct interpretation of the calculated indentation stress–strain response is intricated by uncertainties in estimating the true contact area. These uncertainties may result from plastic deformation mechanisms, including pile-up, where material accumulates around the indenter, and sink-in, where the surface depresses around the contact region, as well as experimental artifacts such as deviations from the ideal indenter geometry and local surface roughness. Therefore, an inverse numerical framework was employed to mitigate the influence of these post-yield uncertainties and obtain more stable and physically representative plasticity parameters. In this approach, the elasto-plastic properties of the bone samples were estimated using a GA-based inverse optimization framework coupled with FEA. Nanoindentation simulations were performed in ABAQUS [46], while the optimization routine was implemented using an in-house MATLAB [47] code. For FEA, the bone was modeled as an isotropic elastic material, defined by Young’s modulus and Poisson’s ratio, and isotropic hardening characterized by three data points for yield stress and their corresponding strains. The plasticity model follows classical isotropic (von Mises) plasticity with isotropic hardening. This formulation does not account for the influence of hydrostatic stress on yielding and it was adopted here for the computational tractability within the inverse-identification framework. The effect of Poisson’s ratio on the extracted modulus was not the focus of this study. Therefore, an average value of ν = 0.3 was used for bone tissue, consistent with Asgari et al. [48], who reported that varying ν from 0.2 to 0.45 changed the estimated modulus by 18.2% for cortical bone and 19.5% for trabecular bone. Frictionless surface-to-surface contact with small sliding was prescribed in the tangential direction between the indenter and the

PLOS One | https://doi.org/10.1371/journal.pone.0361283 October 23, 2026 8 / 25 sample, while hard contact was defined in the normal direction to avoid penetration and allow contact pressure to develop [33]. The indenter motion was controlled through a Reference Point (RP), to which the prescribed vertical displacement was applied. The bottom boundary of the bone domain was constrained using an ENCASTRE boundary condition. The indentation process was simulated using a 2D axisymmetric model, with the spherical indenter represented as a rigid surface because its stiffness is substantially higher than that of the bone, making indenter deformation negligible. The bone domain was discretized using 2601 CAX4R four-node axisymmetric quadrilateral elements with reduced integration. A mesh sensitivity analysis was performed by reducing the mesh size until the reaction force recorded at the RP converged to a stable value for a representative test case. In addition, local mesh refinement was applied in the contact region to improve the accuracy of the indentation response. The mesh was spatially graded, with an element edge length of approximately 1 μm in the refined contact region and up to around 10 μm in the coarser regions away from the indentation site. The loading phase of the FEA nanoindentation test was simulated by incrementally applying the experimental maximum penetration depth under static, nonlinear conditions, with reaction forces at the RP extracted from the ABAQUS output. Fig 4A shows the static axisymmetric FEA setup used to simulate the spherical nanoindentation tests. Fig 4. FEA simulation and GA-based inverse optimization framework for spherical nanoindentation. (A) FEA simulation setup replicating the nanoindentation experiment, showing the discretized geometry with refined mesh near the contact region and the resulting post-indentation stress contour. Contour plot of von Mises stress, consistent with the formulation adopted in the constitutive model, is reported for visualization of the simulated stress field only. (B) Flowchart of the inverse optimization framework used to determine elasto-plastic material properties from nanoindentation data. The optimized FEA load (P opt ) is obtained from the reaction force at the RP for the prescribed indentation displacement and is compared with the experimental load–depth response during optimization. https://doi.org/10.1371/journal.pone.0361283.g004

PLOS One | https://doi.org/10.1371/journal.pone.0361283 October 23, 2026 9 / 25 The primary output extracted from each FEA simulation was the reaction force at the RP as a function of the prescribed indentation depth. This simulated load–depth response was used in the inverse optimization to identify the elasto-plastic material parameters by comparison with the corresponding experimental response. Further FEA implementation details are provided in S1 Appendix (Section S1.2). The plastic response was defined using three yield stress–strain control points:

x= [ σ 0 y ,ε 0 y ,σ 1 y ,ε 1 y ,σ 2 y ,ε 2 y ] (3) where (σ y 0 , ε y 0 ) represents the initial yield point, (σ y 1 , ε y 1 ) describes an intermediate control point introduced to represent the evolution of the post-yield hardening response, and (σ y 2 , ε y 2 ) is the terminal point within the analyzed strain range. The intermediate point provides flexibility in describing nonlinear hardening rather than representing a separate physical yielding event. These three points define the piecewise isotropic hardening behavior in ABAQUS, where ε i y (i= 0, 1, 2)

denotes the corresponding total uniaxial strain. These parameters served as optimization design variables. The GA iteratively updated these parameters by minimizing the difference between the experimental load–depth response obtained from nanoindentation and the corresponding FEA-predicted response, allowing the optimized elasto-plastic material properties to be identified. This framework is illustrated in Fig 4B. To ensure a physically realistic elasto-plastic response, the optimized stress–strain points were constrained to follow a monotonic hardening behavior:

ε 0 y ≤ε 1 y ≤ε 2 y σ 0 y ≤σ 1 y ≤σ 2 y (4) These constraints are informed by the observed behavior of the nanoindentation stress–strain curve, which demonstrates a positive correlation between stress and strain. The terminal strain was bounded at 3%, and all simulations remained within the calibrated hardening range, avoiding extrapolation beyond the final defined point. The inverse optimization problem was formulated by minimizing the Mean Squared Error (MSE) between the experimental and FEA-predicted load– depth curves:

min x J ( x ) = 1 N s N s ∑ i=1 [ ̃ P exp ( h i ) – ̃ P opt ( h i ,x ) ] 2 (5) where P̃ exp and P̃ opt are the experimental and simulated indentation loads obtained from the 12 th -degree polynomial fit at indentation depth h i , respectively, and N s = 1000 is the number of evenly spaced sample points between 0 and h exp max , used for curve comparison. The polynomial fitting provided a smooth representation of both responses and enabled direct comparison at identical penetration depths. This becomes important for evaluating the objective function of the optimization problem. A polynomial-order sensitivity assessment is provided in Section S1.1 of S1 Appendix. The GA iteratively updated the material parameters until either the maximum of 15 generations was reached or the best fitness value showed no further improvement for five consecutive generations. This stopping strategy was selected to balance convergence accuracy with computational cost, since each fitness evaluation required a separate FEA simulation. Since GA is stochastic in nature, no gradient information is needed here. This approach is advantageous as deriving gradient expressions for such a highly non-convex optimization problem would be exceedingly complex. To assess optimization repeatability, a representative central-diaphysis cortical test in the tangential direction was independently optimized three times using different initial populations. Details of the GA implementation and repeatability assessment are provided in S1 Appendix (see Section S1.2).

PLOS One | https://doi.org/10.1371/journal.pone.0361283 October 23, 2026 10 / 25 2.3. Micro-to-continuum scale material mapping To bridge tissue-scale mechanical properties with continuum-level material inputs for conventional FEA, the optimized material parameters were incorporated into a homogenization scheme and material mapping framework. The localized nanoindentation measurements were not directly extrapolated throughout the bone; rather, they were used as region-specific tissue properties and combined with regional μQCT-derived architectural and density information to establish compartment-specific continuum relationships. Because cortical bone has a relatively dense microstructure compared with trabecular bone, its continuum-level mechanical response was assumed to be closely related to its tissue-level properties. Hence, the optimized microscale cortical bone properties were considered representative of the continuum-scale (i.e., macroscale) cortical material response in this study. In contrast, trabecular bone has a highly porous and architecturally complex structure, making a direct tissue-to-continuum equivalence inappropriate. Therefore, two Representative Volume Elements (RVEs) were randomly extracted from μQCT images of each ROI of the canine femur to capture region-specific trabecular architecture and derive effective elastic moduli through homogenization. The μQCT images were acquired at a spatial resolution of 20 μm, and cubic RVEs with a side length of 2 mm were chosen to provide a continuum-scale representation of the local trabecular microstructure. Although the RVEs were randomly selected, they were chosen to capture the repeating microstructural patterns characteristic of trabecular bone within each ROI. The selections aimed to reflect trabecular structures comparable to those examined by nanoindentation, while also incorporating additional regional architectures identified in the μQCT images. Thus, the RVEs were not necessarily spatially coincident with the nanoindentation sites. Nanoindentation provided tissue-scale properties, whereas the RVEs captured architecture-dependent effective behavior. Fig 5A illustrates the selected ROIs and their corresponding RVEs across different anatomical locations of the canine femur. Each RVE was voxelized using a polygon mesh voxelization algorithm and discretized into a regular finite element unit cell [49]. Six independent unit strain cases were applied to each RVE, including three normal and three shear loading modes, to calculate the homogenized stiffness tensor and the corresponding effective elastic properties. Although the solid bone tissue was assumed to be locally isotropic, the homogenized RVE response was not constrained to isotropy. The six independent loading cases allowed the full homogenized stiffness tensor to be determined, thereby capturing the direction-dependent elastic response of the trabecular architecture. The FEA approximation of the homogenized stiffness tensor for a unit cell with a volume of |Y| is given by:

E H ijkl = 1 |Y| N e ∑ e=1 (u A(ij) e ) T k e u A(kl) e (6) In this equation, N e is the number of elements, k e is the element stiffness matrix, and u A(ij) e and u A(kl) e are the element displacement fields associated with the applied unit strain fields [50]. Assuming locally isotropic elasticity for the solid bone tissue constituting each voxel, the element stiffness matrix for an element with volume Ω e is:

k e = ∫ Ω e B T CBdΩ e (7) Here B is the strain–displacement matrix and C is the constitutive matrix of the solid bone tissue. The constitutive matrix is defined using Lamé parameters:

λ= νE ( 1+ν)(1–2ν ) ,μ= E 2(1+ν) (8) where E and ν are the tissue-scale elastic modulus and Poisson’s ratio, respectively. Note that the Lamé parameters were derived directly from E and ν and used only to define the element-level constitutive matrix for homogenization.

PLOS One | https://doi.org/10.1371/journal.pone.0361283 October 23, 2026 11 / 25 In this work, the homogenization procedure proposed by Dong et al. [51] for cellular materials was adopted. This approach involved using a voxelization algorithm to project a structure onto a finite element mesh with 3D solid elements. All microstructures were discretized into a unit cell having 100 × 100 × 100 elements. More information on RVE extraction, the homogenization formulation, and the resulting orthotropic effective properties is provided in Section S1.3 of S1 Appendix. The homogenized elastic properties were used to establish the continuum-scale modulus–density relationship, while the corresponding yield and post-yield parameters were subsequently assigned through the E-dependent interpolation procedure. Following homogenization, a density-based material mapping scheme, illustrated in Fig 5B, was developed to assign spatially varying elastic properties to the finite element model. This approach allowed the trabecular compartment to be represented as an equivalent continuum rather than as an explicitly resolved porous architecture, which is not feasible using normal CT resolution. Note that standard phantom calibration was used to convert CT intensity into calibrated density. For trabecular bone, the average HU of each 2 × 2 × 2 mm 3 RVE from different ROIs was converted to apparent density (ρ app ) and paired with its homogenized effective modulus, E eff trab , such that each RVE provided an E eff trab –ρ app data point. For cortical bone, the average HU of each cortical region was similarly converted to ρ app and paired with the optimized Fig 5. Micro-to-continuum scale material mapping framework. (A) RVEs extracted from femoral head (RVE 11 and RVE 12 ), femoral neck (RVE 21 and RVE 22 ), greater trochanter (RVE 31 and RVE 32 ), distal metaphysis (RVE 41 and RVE 42 ), and distal condyle (RVE 51 and RVE 52 ), where the first index denotes the anatomical region and the second index distinguishes the two RVEs extracted from that region; and (B) workflow for deriving compartment-specific E(HU) relationships and spatially consistent elasto-plastic material properties for FEA. https://doi.org/10.1371/journal.pone.0361283.g005

PLOS One | https://doi.org/10.1371/journal.pone.0361283 October 23, 2026 12 / 25 nanoindentation-derived modulus to obtain an E cort –ρ app relationship. Suggested by Helgason et al. [52], a power-law relationship was used to describe both trabecular and cortical bone E–ρ app correlation:

E(ρ app )= { α trab ρ β trab app α cort ρ β cort app (9) where α and β are fitting coefficients determined separately for the trabecular and cortical bone compartments. These compartment-specific E–ρ app relationships can be combined with the phantom-derived ρ app –HU calibration to define E eff trab (HU) and E cort (HU) , which enables patient-specific material assignment for both cortical and trabecular regions. Therefore, the final compartment-specific elastic modulus map can be defined as:

E(HU)= { f trab ( ρ(HU) ) HU<HU th f cort ( ρ(HU) ) HU≥HU th (10) where f trab and f cort are the trabecular and cortical E–ρ app functions, respectively, and HU th is the threshold separating trabecular- and cortical-dominant regions. This threshold is protocol-dependent and may vary with CT acquisition settings, reconstruction parameters, and calibration procedures; therefore, it should be determined using calibration phantom data when available. Plasticity parameters also can be interpolated as functions of E(HU) to assign spatially consistent elasto-plastic properties. For FEA material assignment, E(HU) was used as the intermediate link between CT intensity and the optimized plasticity parameters. Each experimentally calibrated elastic modulus was associated with a corresponding set of plasticity parameters obtained from the inverse optimization, including the initial yield and subsequent hardening stress–strain points. Therefore, when the modulus calculated for a given HU interval corresponded to one of the calibrated values, the associated optimized plasticity parameter set was assigned directly. For HU intervals producing intermediate modulus values, the corresponding plasticity parameters were obtained by interpolation between the two neighboring calibrated material sets. For a general plasticity parameter p, this can be expressed as:

p ( E i ) =p j + E i –E j E j+1 –E j ( p j+1 –p j ) (11) where E i is the target elastic modulus, E j and E j+1 are the neighboring calibrated elastic moduli, and p j and p j+1 are their corresponding optimized plasticity parameters. This procedure was applied separately to each parameter, p∈{σ y 0 , ε y 0 , σ y 1 , ε y 1 , σ y 2 , ε y 2 }, allowing each HU interval to be assigned a complete elasto-plastic material card. This mapping assumes that, within each bone compartment, the optimized plasticity parameters vary smoothly between the experimentally calibrated material states and that their association with the corresponding elastic modulus is representative over the calibrated range. The same constitutive formulation was maintained for all interpolated material sets, and cortical and trabecular properties were treated separately. Thus, HU was first used to determine E through the established E(HU) relationship, and the corresponding plasticity parameters were then assigned through E-dependent interpolation between the neighboring calibrated material sets. 3. Results 3.1. Stress–strain curves The stress–strain curves derived from nanoindentation are shown in Fig 6. Multiple indentations were performed on each sample to ensure experimental repeatability, and outliers were excluded. The spherical indentation-derived stress– strain curves showed clear site-dependent mechanical behavior, reflecting the heterogeneous nature of the bone tissue.

PLOS One | https://doi.org/10.1371/journal.pone.0361283 October 23, 2026 13 / 25 Although variability was observed among indentation points within the same anatomical region, the responses within each site generally followed a similar trend, suggesting that tissue properties were more consistent within a given location than across different anatomical regions. 3.2. Elasto-plastic parameters The elasto-plastic material properties calculated directly from the experiments and the equivalent parameters obtained through the inverse optimization procedure are presented in Fig 7. At each anatomical location, 3–5 replicate indentations Fig 6. Stress–strain curves derived from spherical tip nanoindentation. Increased noise and oscillations were observed after the yield point, primarily due to greater uncertainty in contact area estimation during post-yield deformation. Note: red circles indicate the approximate indentation locations on the CT images and do not represent individual indentation points. https://doi.org/10.1371/journal.pone.0361283.g006

PLOS One | https://doi.org/10.1371/journal.pone.0361283 October 23, 2026 14 / 25 were analyzed, and the reported material parameters are presented as the corresponding mean ± SD (i.e., Standard Deviation). These quantitative material parameters further demonstrate regional variation within the examined femur. The experimentally derived elastic moduli were generally higher than the optimized values, with a mean absolute symmetric difference of around 15.97%, indicating moderate agreement. This difference may result from estimating the modulus directly from the local slope near the apparent yield point. Near this transition, the slope is sensitive to smoothing, polynomial fitting, local oscillations, and strain-window selection, which may overestimate stiffness. For a representative cortical test, reducing the polynomial order from 12 to 8 changed the extracted elastic modulus by only 1.1%, while the apparent initial yield stress and strain varied by 9.1% and 8.3%, respectively. Additional details are provided in Section S1.1 of the S1 Appendix. Across the tested regions, the longitudinal cortical sample from the central diaphysis showed the highest elastic modulus, with an optimized value of 14.80 ± 0.49 GPa. Lower moduli in the radial and tangential directions reflected the orientation-dependent stiffness of cortical bone. The optimized initial apparent yield strains were clustered within a narrow range, mainly around 0.6–0.7%. This limited variation is expected because indentation strain represents a localized contact response rather than a true continuum Fig 7. Elasto-plastic material properties obtained from the nanoindentation experiments and optimization framework. (A) elastic modulus, (B) initial and maximum apparent yield strains, (C) initial and maximum apparent yield stresses, and (D) average reproducibility of the experimental and optimized data expressed as the Coefficient of Variation, CV (%). The sample size for each location is indicated above the corresponding group in panel (A) and applies to panels (B) and (C). Abbreviations: Cort., cortical; Trab., trabecular; meta., metaphysis; L, longitudinal; T, tangential; R, radial; Exp., experimental; Opt., optimized; CV, coefficient of variation; SD, standard deviation. https://doi.org/10.1371/journal.pone.0361283.g007

PLOS One | https://doi.org/10.1371/journal.pone.0361283 October 23, 2026 15 / 25 strain field, with highly nonuniform strain concentrated beneath the spherical indenter. Thus, regional differences were more evident in modulus, yield stress, and post-yield response than in initial apparent yield strain. In contrast, the optimized maximum apparent yield strain showed greater variation, ranging from approximately 1.98% to 2.49%. The highest value was observed in the trabecular femoral head (2.49 ± 0.11%), consistent with the greater compliance and deformation capacity of trabecular bone. The optimized yield stress parameters showed clearer anatomical site dependence than the yield strains. The highest load-bearing response was observed in the longitudinal cortical direction of the central diaphysis, with an optimized initial apparent yield stress of 101.27 ± 8.71 MPa and a maximum apparent yield stress of 254.28 ± 13.05 MPa. The optimized maximum apparent stresses were generally higher than those estimated directly from the experiments, with a mean absolute symmetric difference of approximately 22.33%. This larger difference, compared with the elastic modulus estimates, reflects the greater dispersion and uncertainty in the post-yield region. The apparent experimental post-yield values should not be interpreted as direct counterparts of the optimized intermediate and terminal hardening parameters, which were inverse-identified from the force–displacement response. To quantify the reproducibility and reliability of both the experimentally derived and optimized parameters, the Coefficient of Variation (CV) was calculated for each anatomical region using the corresponding mean and SD. The regional CV values were then summarized as the average CV ± SD across all regions, while the detailed region-specific CV values are provided in Table S2 and Table S3 of S1 Appendix. For the optimized parameters, the average CV values showed moderate variability, ranging from approximately 10.8% to 19.6%. The elastic modulus showed relatively consistent results, with average CV values of 10.81 ± 5.32% for the optimization framework. Yield-related parameters showed slightly higher variability, particularly the maximum apparent yield strain, with CV values of 18.65 ± 4.98% after optimization. The observed variability in the optimized values suggests that the framework preserves anatomical and tissue-level differences instead of excessively smoothing the material response. The optimized plasticity parameters and MSE values are presented in Table 1. These parameters can be used in microscale computational frameworks to define the plastic region of the constitutive model and to support potential damage initiation criteria based on the maximum apparent stress and strain. For each anatomical region, the optimized elastic modulus and plastic stress–strain parameters were combined to define a region-specific elasto-plastic material model. The quality of the optimized parameter set was evaluated by comparing the experimental and optimized force–displacement responses. The region-specific MSE values ranged from 2.66 to 9.88 (mN) 2 , showing that the optimized models closely reproduced the experimental indentation responses. These errors were small compared with the corresponding force levels, indicating that the optimization procedure provided a reliable fit and could extract mechanically consistent Table 1. Optimized plasticity parameters from the GA-based inverse optimization framework. RegionBone TypeOptimized Plasticity ParametersMSE (mN) 2 σ 0 y (MPa) ε 0 y (%)σ 1 y (MPa) ε 1 y (%)σ 2 y (MPa) ε 2 y (%) FHCortical55.4 ± 10.60.66 ± 0.07170.9 ± 21.41.44 ± 0.41205.5 ± 25.62.47 ± 0.394.44 ± 2.83 Trabecular43.7 ± 8.70.67 ± 0.16113.2 ± 27.41.26 ± 0.38191.1 ± 28.62.49 ± 0.115.75 ± 3.31 PMCortical66.4 ± 7.50.67 ± 0.06162.6 ± 37.91.13 ± 0.08235.4 ± 26.91.98 ± 0.322.75 ± 0.93 CDCortical – L101.3 ± 8.70.68 ± 0.04230.6 ± 27.51.17 ± 0.10254.3 ± 13.02.23 ± 0.504.98 ± 0.56 Cortical – T32.5 ± 5.10.53 ± 0.05108.8 ± 57.41.14 ± 0.15204.9 ± 13.62.35 ± 0.362.66 ± 1.83 Cortical – R23.3 ± 4.20.45 ± 0.08136.0 ± 29.41.39 ± 0.60212.2 ± 28.92.18 ± 0.635.70 ± 4.03 DMCortical47.5 ± 9.30.61 ± 0.09138.5 ± 18.31.06 ± 0.22157.1 ± 26.62.06 ± 0.425.28 ± 2.66 Trabecular39.1 ± 9.70.62 ± 0.03144.0 ± 17.11.15 ± 0.16191.3 ± 19.72.21 ± 0.579.88 ± 16.06 The parameters are reported for femoral head (FH), proximal metaphysis (PM), central diaphysis (CD), and distal metaphysis (DM), including initial yield, intermediate hardening, maximum apparent stress–strain values, and the corresponding fitting MSE. Note: For CD cortical samples, L = longitudinal, T = tangential, and R = radial. https://doi.org/10.1371/journal.pone.0361283.t001

PLOS One | https://doi.org/10.1371/journal.pone.0361283 October 23, 2026 16 / 25 elasto-plastic parameters for each region. Representative comparisons showed close agreement throughout the indentation depth and are provided in S2 Fig and Section S1.2 of the S1 Appendix. For a representative cortical test, three independent GA runs with different initial populations produced comparable force–displacement fits (MSE = 1.67–1.91 (mN) 2 ). The initial yield parameters and terminal hardening stress showed low variability (CV = 0.55–1.12%), whereas the intermediate hardening parameters showed greater variation (approximately 13%). More details are provided in Section S1.2 of the S1 Appendix. 3.3 Continuum-scale material properties The HU–ρ app relationship was estimated using two calibration phantoms scanned during μQCT with known densities of 0.25 and 0.75 g/cm 3 . The resulting calibration equation gives:

ρ app =7×10 –4 HU ∗ +3.57×10 –2 (12) where HU * is the protocol-dependent HU. Although the HU ∗ –ρ app calibration is protocol-dependent, converting HU * to ρ app allows the homogenized effective modulus, E eff , to be expressed through an E–ρ app relationship, reducing direct dependence on raw image intensity. The trabecular RVEs were initially assigned E = 6.53 GPa and ν = 0.3, based on the optimized properties of the femoral head trabecular samples. For RVE 41 and RVE 42 , extracted from the distal metaphysis, E = 7.74 GPa and ν = 0.3 were used to represent the relatively porous cortical–trabecular transition region. The maximum directional effective modulus obtained from homogenization was selected as the primary load-bearing modulus and correlated with the corresponding apparent density values to define the E trab eff –ρ app relationship for material assignment. For both trabecular and cortical bone, apparent density was calculated from 2 × 2 × 2 mm 3 μQCT-derived sub-volumes. These correlations are illustrated in Fig 8. Detailed homogenization results are provided in S1 Appendix (Table S4). The fitted E–ρ app relationships were then used to assign spatially varying elastic properties to the trabecular- and cortical-dominant compartments. Separate correlations were defined for each compartment to account for differences in their effective E–ρ app response. The final compartment-specific elastic modulus map was defined as:

E ( ρ app ) = { 7.584 ρ 1.273 app trabecular 8.904ρ 2.035 app cortical (13) Fig 8. Modulus–density correlations derived through power-law curve fitting. (A) Trabecular and (B) cortical bone regions. Trabecular data points represent μQCT-derived RVE apparent densities paired with effective moduli obtained from homogenization. Cortical data points represent μQCT-derived apparent densities paired with the corresponding region-specific average elastic moduli obtained from the optimization. The resulting fitted relationships were used to define compartment-specific continuum-scale material properties. https://doi.org/10.1371/journal.pone.0361283.g008

PLOS One | https://doi.org/10.1371/journal.pone.0361283 October 23, 2026 17 / 25 For this study, considering the CT imaging protocol and the observed HU * ranges, Eqs 12 and 13 were combined to define the elastic modulus map as a function of HU * . Voxels with HU * ≥ 500 were considered cortical-dominant regions, while voxels with HU * < 500 were considered trabecular-dominant regions. Therefore, the elastic modulus map was defined as:

E ( HU ∗ ) =      7.584 ( 7×10 –4 HU ∗ +3.57×10 –2 ) 1.273 HU ∗ <500 8.904 ( 7×10 –4 HU ∗ +3.57×10 –2 ) 2.035 HU ∗ ≥500 (14) In addition to elastic mapping, the optimized plasticity parameters were interpolated as functions of E(HU * ) to assign spatially consistent elasto-plastic properties across the finite element model. Accordingly, the yield and post-yield parameters were assigned based on the local elastic modulus obtained from the compartment-specific E(HU * ) relationship, allowing both elastic and plastic responses to reflect regional tissue heterogeneity. The resulting material definitions therefore included E together with σ y 0 , ε y 0 , σ y 1 , ε y 1 , σ y 2 , and ε y 2 . The complete elasto-plastic parameter sets assigned to the HU *

intervals are summarized in Table 2. For each HU * interval, a representative elastic modulus was calculated from Eq 14 using the midpoint HU * value of that interval, and the corresponding plasticity parameters were obtained through the E-dependent interpolation described in Eq 11. To demonstrate continuum-scale material assignment, the canine femur RVEs were color-mapped using the indentation-derived bone tissue modulus values as inputs for homogenization, as shown in Fig 9A. The corresponding continuum-scale elements were then assigned the homogenized properties obtained for each RVE. The effective elastic modulus of the homogenized continuum elements was slightly lower than the tissue-level modulus because it accounts for the influence of porosity and trabecular architecture. The whole femur was then segmented from μQCT images, and an adaptive mesh with an element size of 1.0 mm was generated to depict material assignment, as shown in Fig 9B. For each element, the average grayscale value of the μQCT voxels contained within that element was approximated as the equivalent CT grayscale value for material assignment. Eq 14 was then used to assign compartment-specific elastic modulus to the continuum-scale canine femur model, while the corresponding plasticity parameters were assigned using the E-dependent interpolation procedure described in Eq 11 and Table 2. Although the spatial map in Fig 9 is visualized using elastic modulus, each HU * interval represents the corresponding complete elasto-plastic material parameter set reported in Table 2. To demonstrate the broad applicability of the approach, the proposed material-mapping was applied to other clinical CT-based models of the canine humerus, tibia, and radius for macroscale FEA simulations, as shown in Fig 10. Since Table 2. Elasto-plastic material properties for continuum FEA using the compartment-specific E(HU * ) relationship and E-dependent interpolation of the optimized plasticity parameters. HU * range Bone type E (GPa) σ 0 y (MPa) ε 0 y (%) σ 1 y (MPa) ε 1 y (%) σ 2 y (MPa) ε 2 y (%) 80–289Trabecular HU * < 5000.7611.81.07318.81.38224.02.057 290–4991.7218.51.07530.41.38638.82.062 500–680Cortical HU * ≥

500 1.7418.81.07630.91.38639.42.072 681–8612.8931.31.08052.41.39266.92.073 862–10414.3346.81.08174.71.39395.12.073 1042–12226.0665.61.082103.41.393131.82.080 1223–14028.1087.91.085138.11.398176.52.080 1403–158310.43113.11.084177.91.398227.12.083 1584–176313.06142.21.088207.11.403239.42.087 1764–195016.00175.11.095237.61.411249.22.100 https://doi.org/10.1371/journal.pone.0361283.t002

PLOS One | https://doi.org/10.1371/journal.pone.0361283 October 23, 2026 18 / 25 the clinical CT voxel size in these datasets was approximately 500–900 μm, the trabecular microarchitecture could not be explicitly resolved. Accordingly, trabecular regions were represented using equivalent continuum properties rather than direct modeling of individual trabeculae. For each HU * interval, the elastic modulus was determined from the compartment-specific relationship, and the corresponding yield and post-yield parameters were assigned using the E-dependent interpolation procedure described in Eq 11 and Table 2. The resulting whole-bone meshes contained 782,856 tetrahedral elements for the humerus (0.8 mm element size), 671,302 for the tibia (0.8 mm), and 985,394 for the radius (0.85 mm). The representative femur model contained 1,121,156 elements (1.0 mm). 4. Discussion The integrated experimental–numerical pathway developed in this study proposes a material mapping approach for assigning site- and compartment-specific elasto-plastic properties to bone in conventional patient-specific FEA. The Fig 9. RVE homogenization and continuum-scale material assignment in the canine femur. (A) RVEs extracted from different anatomical regions of the femur, color-mapped using the indentation-derived tissue-level elastic modulus and homogenized to obtain the corresponding effective elastic moduli, E trab eff . (B) Continuum-scale femur mesh used to illustrate compartment-specific material assignment based on the HU ∗ –ρ app relationships. Trabecular pores were filled for continuum modeling, and a 1-mm cortical shell is shown in beige (E ≈ 10.60 GPa). Teal-blue regions in the RVEs are visualization artifacts at pore–bone transitions only; each RVE was assigned a single modulus before homogenization. https://doi.org/10.1371/journal.pone.0361283.g009

PLOS One | https://doi.org/10.1371/journal.pone.0361283 October 23, 2026 19 / 25 results show that spherical nanoindentation can capture tissue-level mechanical responses across different anatomical sites, while the GA-based inverse optimization procedure reduces reliance on post-yield contact-area estimation. This provides more stable and mechanically consistent material parameters, particularly in the post-yield region, compared with direct interpretation of indentation-derived stress–strain curves. By combining the optimized tissue-scale properties with RVE homogenization and E–ρ app correlations, the proposed pathway links microscale measurements to continuum-scale material maps for patient-specific FEA models reconstructed from clinical CT images, where trabecular microarchitecture cannot be explicitly resolved. The observed spatial variation emphasizes the importance of comprehensive region-specific characterization, as different anatomical sites are subjected to distinct loading modes, loading directions, and functional demands. These local mechanical environments can influence tissue organization, density, mineralization, and overall mechanical response [53–55]. Therefore, testing multiple regions provides a more representative basis for capturing bone heterogeneity and developing spatially informed material properties for FEA. Another major observation was the increased dispersion and oscillatory behavior of the calculated stress–strain curves after the onset of yielding. While the initial elastic region showed relatively smoother and more consistent behavior, the yield and post-yield regions exhibited greater fluctuations. These oscillations may arise from a combination of localized plastic deformation, microstructural heterogeneity, and uncertainties in contact-area estimation. As discussed by Pathak and Kalidindi [34], pile-up and sink-in effects, changes in contact radius, non-ideal indenter geometry, and specimen surface conditions can influence the calculated indentation strain and stress after plastic deformation begins. These effects introduce uncertainty in the extraction of plasticity parameters and further support the use of a numerical framework to regularize the post-yield response. Epoxy embedding may introduce local mechanical constraint or support to the bone tissue, particularly in porous trabecular regions where resin infiltrates adjacent pores. However, the magnitude of this effect depends on both the embedding condition and the indentation sampling volume. Bushby et al. [53] showed that hydration and PMMA embedding can alter the measured indentation modulus of bone, while also demonstrating that larger-radius spherical indenters and higher loads increase the sampled material volume and reduce sensitivity to localized near-surface effects. In the present study, a 158 μm diameter spherical indenter was used, and indentations were positioned within the bone tissue and away from visible bone–epoxy interfaces, which was expected to reduce direct surface and boundary effects. Mittra et al. [20] further reported that substantial variations in epoxy stiffness did not significantly affect the measured elastic modulus of canine trabecular bone, although hardness was influenced. Nevertheless, local confinement or mechanical support Fig 10. Application of the proposed compartment-specific material-mapping approach to clinical CT-based models of the canine (A) humerus, (B) tibia, and (C) radius. Representative sections illustrate spatial variation in assigned elastic modulus, with higher-modulus cortical regions and trabecular regions represented using a continuum mesh rather than computationally expensive fine-scale trabecular modeling. https://doi.org/10.1371/journal.pone.0361283.g010

PLOS One | https://doi.org/10.1371/journal.pone.0361283 October 23, 2026 20 / 25 resulting from epoxy infiltration, particularly around trabecular struts, cannot be completely excluded as a source of measurement uncertainty. Previous canine bone studies have mainly focused on cortical bone and have commonly reported elastic modulus, while trabecular bone properties and post-yield behavior remain less characterized. The longitudinal cortical diaphyseal modulus obtained in the present study (14.80 ± 0.49 GPa) was comparable to values previously reported for hydrated canine femoral cortical bone by Lee et al. [18] (13.41 ± 5.70 GPa) and Autefage et al. [54] (15.60 ± 2.6 GPa), and also fell within the range reported by Luo et al. [19] (approximately 15–22 GPa). Although the elastic modulus derived in the current study is generally comparable to reported hydrated values, this agreement may still be influenced by specimen-specific factors, including bone mass density and anatomical region. Hydration condition is nevertheless known to influence bone stiffness; for example, Lee et al. [55] reported elastic moduli of approximately 22–25 GPa for dry canine femoral cortical bone compared with approximately 13–15 GPa under wet conditions. The relatively lower modulus obtained in the present study under dry conditions may reflect differences in indentation geometry, specimen preparation, and stress–strain analysis. Therefore, comparisons with literature values should be interpreted in the context of these methodological differences. The above-mentioned studies therefore establish a useful reference range for the elastic modulus of hydrated canine femoral cortical bone; however, their scope was primarily limited to elastic characterization rather than full elasto-plastic stress–strain determination. Furthermore, Luo et al. [19] identified trabecular bone measurement as a major limitation, emphasizing the difficulty of fully characterizing both cortical and trabecular compartments. The variation in modulus values reported by Lin et al. [56] for canine femoral cortical bone (25.7 GPa) and by Mittra et al. [20] for dry canine femoral trabecular bone (12.97 ± 4.15 GPa) may be partly explained by differences in anatomical site, specimen condition, indenter geometry, and analysis method, particularly when modulus is extracted from the unloading response. Although lower than the value reported by Mittra et al. [20], the trabecular modulus obtained from the present dry specimens was of a similar magnitude. Overall, these comparisons suggest that the cortical elastic moduli obtained in this study are consistent with reported hydrated canine bone values, while the present work extends previous studies by incorporating trabecular regions and deriving elasto-plastic parameters. As discussed previously, the benefit of the inverse-identification framework is particularly important for the post-yield response. The indentation-derived stress–strain curve provides initial estimates of the elastic modulus and apparent yield point; however, its direct interpretation becomes increasingly uncertain after yielding because plastic deformation alters the evolving contact geometry. The GA-based inverse optimization procedure therefore uses the experimental load–depth response to refine the constitutive parameters and identify the intermediate and terminal hardening points within the calibrated indentation range. This provides a complete elasto-plastic material description without prescribing an arbitrary post-yield hardening response. The repeatability assessment further showed that the initial yield parameters and terminal hardening stress were consistently identified across independent GA runs, whereas the intermediate hardening point was less tightly constrained. This indicates good robustness of the principal constitutive parameters, although some non-uniqueness remains in the intermediate hardening description. Another key advantage of this framework is that it reduces the need to explicitly model trabecular microarchitecture in macroscale bone FEA. By deriving density-based elasto-plastic material maps, the effective continuum response of trabecular bone can be incorporated without requiring complex reconstruction from μQCT data or computationally expensive trabecular meshing. This is particularly important for patient-specific FEA derived from clinical images, where rapid model generation, computational efficiency, and numerical stability are essential. The resulting material maps can support higher-fidelity estimation of damage initiation, fracture risk, and load-bearing capacity. The power-law model, E=αρ β app , used to fit the developed E–ρ app relationship is consistent with formulations reported in previous canine bone studies [25,57]. However, because reported modulus–density relationships vary with anatomical site, density definition, and testing method, the present relationships should be interpreted within the anatomical and experimental conditions investigated in this study [25,58]. In future studies, these relationships may also be adapted to degraded bone conditions, such

PLOS One | https://doi.org/10.1371/journal.pone.0361283 October 23, 2026 21 / 25 as osteosarcoma-associated bone loss or osteoporosis, provided that appropriate density- and pathology-specific correction factors are incorporated. Figs 9 and 10 demonstrated the application of the proposed material-mapping framework to whole-bone continuum FEA models in which trabecular microarchitecture is represented through homogenized material properties rather than explicit trabecular geometry. The resulting models contained approximately one million tetrahedral elements with element sizes of 0.8–1.0 mm. High-resolution FEA models that explicitly resolve individual trabecular architecture require substantially finer discretization and several million elements. For instance, Van Rietbergen et al. [59] reported approximately 7.6 million elements for a canine proximal femur, while approximately 2–21 million elements have been reported for localized human and murine bone regions [60,61]. This comparison illustrates the computational advantage of representing trabecular bone through continuum-scale homogenized properties rather than explicitly resolving individual trabeculae in wholebone FEA studies. Although this study was motivated by the limited availability of elasto-plastic material data for canine long bones, the proposed framework is not limited to a single species, anatomical site, or bone type. The same methodological workflow can be adapted to other bones, species, age groups, or pathological conditions, provided that suitable imaging and experimental data are available. In this context, the canine femur is presented as a representative application of the framework rather than the limit of its broader use. The application to the humerus, tibia, and radius demonstrates how compartment-specific continuum material maps can be implemented in whole-bone models without explicitly resolving trabecular microarchitecture, thereby maintaining a computational scale suitable for nonlinear whole-bone FEA. As a proof-of-concept study, the present framework was developed using a selected set of anatomical regions and a single canine femur. Trabecular characterization was focused on the femoral head and distal metaphysis, where sufficiently prominent trabecular architecture was available for nanoindentation. In addition, the RVEs were selected to represent regional trabecular architecture rather than being spatially co-localized with individual indentation sites; therefore, a direct one-to-one correspondence between local tissue properties and specific RVE architecture was not established. The homogenization procedure captured the architecture-dependent elastic response through the effective stiffness tensor, while the progressive trabecular yielding and load redistribution were incorporated at the continuum level through the subsequent E-dependent interpolation of yield and post-yield parameters rather than being explicitly homogenized. Because the study was based on a single femur, the observed regional differences should be interpreted as within-specimen variations. Future studies incorporating additional trabecular regions, larger and well-characterized cohorts, and more comprehensive directional testing will be needed to evaluate the generalizability of the proposed material relationships and further develop the framework toward a fully orthotropic elasto-plastic characterization. 5. Conclusion Clinical and preclinical assessments increasingly rely on numerical simulations such as FEA to estimate bone load-bearing capacity under different conditions, including pathological cases and the evaluation of biomedical devices intended to reinforce bone. Although FEA is a well-established tool in biomechanics, its clinical and translational use requires material modeling strategies that are both reliable and computationally efficient. The framework proposed in this study addresses this need by translating tissue-scale mechanical properties into continuum-scale material inputs that can be directly utilized in whole-bone macroscale FEA models. This is particularly important for canine long bones, where the literature still lacks sufficient experimentally derived material data for veterinary FEA applications, although the same concept may also be extended to other species, including humans. Many CT-based bone models assign material properties using global values or empirical relationships with grayscale intensity and density. However, these approaches may overlook regional variations and the mechanical influence of trabecular microarchitecture. The proposed framework addresses this gap by incorporating homogenized trabecular properties into continuum-scale material maps, allowing whole-bone FEA models to account for trabecular architecture without

PLOS One | https://doi.org/10.1371/journal.pone.0361283 October 23, 2026 22 / 25 explicitly modeling each trabecula. This strategy provides a more practical and mechanically representative material input for heterogeneous bone simulations. Although spherical nanoindentation introduces several challenges, particularly the noisy interpretation of post-yield stress–strain behavior, the proposed GA-based inverse optimization framework provided a practical solution for extracting more stable and mechanically consistent elasto-plastic properties. This is especially important because post-yield behavior plays a key role in predicting damage initiation and progression in bone mechanics. The application of these correlations to four different canine long bones further demonstrates their potential as practical constitutive relationships linking density to material properties in whole-bone FEA. Because these relationships were developed from a single canine femur, further validation across additional specimens is necessary to assess their generalizability, although the same procedure can be applied. Moreover, a direct comparison between the optimized material maps and conventional CT-based material assignments would provide an important next step for evaluating their influence on whole-bone mechanical predictions. Overall, this framework extends the use of experimental data beyond simple property reporting and provides heterogeneous elasto-plastic material maps for future patient-informed biomechanical simulations. Supporting information S1 Appendix. Supplementary methods and results. Additional details regarding spherical nanoindentation calibration and stress–strain formulation, GA-based inverse optimization, RVE reconstruction from μQCT data and homogenization, variability of experimental and optimized material parameters, and homogenized orthotropic properties of trabecular RVEs. (DOCX) S1 Fig. Illustration of the experimental and numerical definition of the elasto-plastic parameters. (A) representative nanoindentation force–displacement response; (B) corresponding indentation stress–strain curve showing the experimentally estimated initial apparent yield point; and (C) schematic representation of the three stress–strain control points used in the inverse optimization, where ( σ 0 y ,ε 0 y ) represents the initial apparent yield point, ( σ 1 y ,ε 1 y ) is the intermediate hardening control point, and ( σ 2 y ,ε 2 y ) is the terminal hardening point within the calibrated strain range. (TIF) S2 Fig. Comparison of experimental and optimized FEA responses for representative cortical samples. (A–C) Experimental and optimized FEA force–displacement curves showing agreement throughout the indentation depth. (D–F) Corresponding apparent indentation stress–strain responses with the inverse-identified constitutive control points ( σ 0 y ,ε 0 y ) , ( σ 1 y ,ε 1 y ) , and ( σ 2 y ,ε 2 y ) . The second and third control points are inverse-identified post-yield parameters and are not expected to coincide directly with the apparent experimental stress–strain response because post-yield contact-area estimation becomes increasingly uncertain. (TIF) Acknowledgments The authors would also like to thank Wayne Papageorge from the Department of Materials Science and Engineering at The Ohio State University for his support. Author contributions Conceptualization: Tareq Zobaer, Janis Lapsley, Do-Gyoon Kim, Laura E. Selmic, Ali Nassiri. Data curation: Behzad Amirzade, Tareq Zobaer. Formal analysis: Behzad Amirzade, Tareq Zobaer, Laura E. Selmic, Ali Nassiri.

PLOS One | https://doi.org/10.1371/journal.pone.0361283 October 23, 2026 23 / 25 Funding acquisition: Laura E. Selmic, Ali Nassiri. Investigation: Behzad Amirzade, Tareq Zobaer, Do-Gyoon Kim, Laura E. Selmic, Ali Nassiri. Methodology: Behzad Amirzade, Tareq Zobaer, Janis Lapsley, Do-Gyoon Kim, Laura E. Selmic, Ali Nassiri. Project administration: Laura E. Selmic, Ali Nassiri. Resources: Laura E. Selmic. Software: Ali Nassiri. Supervision: Laura E. Selmic, Ali Nassiri. Validation: Behzad Amirzade, Janis Lapsley, Do-Gyoon Kim, Laura E. Selmic, Ali Nassiri. Visualization: Behzad Amirzade, Tareq Zobaer. Writing – original draft: Behzad Amirzade, Tareq Zobaer. Writing – review & editing: Janis Lapsley, Do-Gyoon Kim, Laura E. Selmic, Ali Nassiri. References 1. Ibrahim A, Magliulo N, Groben J, Padilla A, Akbik F, Abdel Hamid Z. Hardness, an important indicator of bone quality, and the role of collagen in bone hardness. J Funct Biomater. 2020;11(4):85. https://doi.org/10.3390/jfb11040085 PMID: 33271801 2. Managuli V, Bothra YS, S SK, Gaur P, Ch PL, Racharya. Overview of mechanical characterization of bone using nanoindentation technique and its applications. Eng Sci. 2023;22:820. 3. Endo D, Ogami-Takamura K, Imamura T, Saiki K, Murai K, Okamoto K, et al. Reduced cortical bone thickness increases stress and strain in the female femoral diaphysis analyzed by a CT-based finite element method: Implications for the anatomical background of fatigue fracture of the femur. Bone Rep. 2020;13:100733. https://doi.org/10.1016/j.bonr.2020.100733 PMID: 33294500 4. Saillard E, Gardegaront M, Levillain A, Bermond F, Mitton D, Pialat J-B, et al. Finite element models with automatic computed tomography bone segmentation for failure load computation. Sci Rep. 2024;14(1):16576. https://doi.org/10.1038/s41598-024-66934-w PMID: 39019937 5. Sas A, Tanck E, Sermon A, van Lenthe GH. Finite element models for fracture prevention in patients with metastatic bone disease. A literature review. Bone Rep. 2020;12:100286. https://doi.org/10.1016/j.bonr.2020.100286 PMID: 32551337 6. Soltani Z, Xu M, Radovitzky R, Stadelmann MA, Hackney D, Alkalay RN. CT-based finite element simulating spatial bone damage accumulation predicts metastatic human vertebrae strength and stiffness. Front Bioeng Biotechnol. 2024;12:1424553. https://doi.org/10.3389/ fbioe.2024.1424553 PMID: 39108596 7. Hernández-Salazar CA, Chamorro CE, González-Estrada OA. Characterization of pig vertebrae under axial compression integrating radiomic techniques and finite element analysis. Inventions. 2024;9(2):36. https://doi.org/10.3390/inventions9020036 8. Sadighi A, Taheri M, Black N, Stolle J, Taghvaei M, Boyes M, et al. Finite element analysis of bone remodeling induced by swelling anchors considering heterogeneous properties. Biomech Model Mechanobiol. 2025;24(6):1937–58. https://doi.org/10.1007/s10237-025-02001-1 PMID: 40817952 9. Pervez Y, Stiles C, Yang Z, Pageau A, Ying J, Davidson J, et al. The effect of image reconstruction kernel and density modulus relationship in finite element models of simulated cadaveric acromial loading. J Biomech. 2025;190:112876. https://doi.org/10.1016/j.jbiomech.2025.112876 PMID: 40694945 10. An YH, Draughn RA. Mechanical Properties and Testing Methods of Bone. Animal Models in Orthopaedic Research. CRC Press; 1998. 11. Kim D-G, Huja SS, Lee HR, Tee BC, Hueni S. Relationships of viscosity with contact hardness and modulus of bone matrix measured by nanoindentation. J Biomech Eng. 2010;132(2):024502. https://doi.org/10.1115/1.4000936 PMID: 20370248 12. Kommidi SR, Kim Y-R, Kim D-G. Modeling of viscoelastic deformation and rate-dependent fracture damage in rat bone. Int J Damage Mech. 2024;34(6):920–43. https://doi.org/10.1177/10567895241245716 13. Cyganik Ł, Binkowski M, Kokot G, Rusin T, Popik P, Bolechała F, et al. Prediction of Young׳s modulus of trabeculae in microscale using macro-scale׳s relationships between bone density and mechanical properties. J Mech Behav Biomed Mater. 2014;36:120–34. https://doi. org/10.1016/j.jmbbm.2014.04.011 PMID: 24837330 14. Pawlikowski M, Skalski K, Bańczerowski J, Makuch A, Jankowski K. Stress–strain characteristic of human trabecular bone based on depth sensing indentation measurements. Biocybern Biomed Eng. 2017;37:272–80. https://doi.org/10.1016/j.bbe.2017.01.002 15. Rho JY, Roy ME 2nd, Tsui TY, Pharr GM. Elastic properties of microstructural components of human bone tissue as measured by nanoindentation. J Biomed Mater Res. 1999;45(1):48–54. https://doi.org/10.1002/(sici)1097-4636(199904)45:1<48::aid-jbm7>3.0.co;2-5 PMID: 10397957 16. Rho JY, Tsui TY, Pharr GM. Elastic properties of human cortical and trabecular lamellar bone measured by nanoindentation. Biomaterials. 1997;18(20):1325–30. https://doi.org/10.1016/s0142-9612(97)00073-2 PMID: 9363331

PLOS One | https://doi.org/10.1371/journal.pone.0361283 October 23, 2026 24 / 25 17. Jiroušek O, Němeček J, Kytýř D, Kunecký J. Nanoindentation of trabecular bone – comparison with uniaxial testing of single trabecula. Chem Listy. 2011. 18. Lee K-L, Sobieraj M, Baldassarri M, Gupta N, Pinisetty D, Janal MN, et al. The effects of loading conditions and specimen environment on the nanomechanical response of canine cortical bone. Mater Sci Eng C Mater Biol Appl. 2013;33(8):4582–6. https://doi.org/10.1016/j. msec.2013.07.018 PMID: 24094163 19. Luo C, Liao J, Zhu Z, Wang X, Lin X, Huang W. Analysis of mechanical properties and mechanical anisotropy in canine bone tissues of various ages. Biomed Res Int. 2019;2019:3503152. https://doi.org/10.1155/2019/3503152 PMID: 31341896 20. Mittra E, Akella S, Qin Y-X. The effects of embedding material, loading rate and magnitude, and penetration depth in nanoindentation of trabecular bone. J Biomed Mater Res A. 2006;79(1):86–93. https://doi.org/10.1002/jbm.a.30742 PMID: 16758456 21. Pressel T, Bouguecha A, Vogt U, Meyer-Lindenberg A, Behrens B-A, Nolte I, et al. Mechanical properties of femoral trabecular bone in dogs. Biomed Eng Online. 2005;4:17. https://doi.org/10.1186/1475-925X-4-17 PMID: 15774014 22. Turner CH, Rho J, Takano Y, Tsui TY, Pharr GM. The elastic properties of trabecular and cortical bone tissues are similar: results from two microscopic measurement techniques. J Biomech. 1999;32(4):437–41. https://doi.org/10.1016/s0021-9290(98)00177-8 PMID: 10213035 23. Bhandal J, Boston SE. Pathologic fracture in dogs with suspected or confirmed osteosarcoma. Vet Surg. 2011;40(4):423–30. https://doi. org/10.1111/j.1532-950X.2011.00811.x PMID: 21395621 24. Pope EA, Wavreille VA, Lapsley JL, Green EM, Kisseberth WC, Rabiner R. Use of the IlluminOss photodynamic bone stabilisation system following stereotactic body radiation therapy for limb‐sparing in six dogs with presumptive appendicular osteosarcoma. Vet Comp Oncol. 2026(vco.70082). https://doi.org/10.1111/vco.70082 25. Kuhn JL, Goldstein SA, Ciarelli MJ, Matthews LS. The limitations of canine trabecular bone as a model for human: A biomechanical study. J Biomech. 1989;22(2):95–107. https://doi.org/10.1016/0021-9290(89)90032-8 PMID: 2708399 26. Choi K, Khang G, Goldstein SA. The elastic moduli and fatigue properties of canine trabecular bone tissue. KSME Int J. 2001;15(7):1022–31. https://doi.org/10.1007/bf03185280 27. Pathak S, Vachhani SJ, Jepsen KJ, Goldman HM, Kalidindi SR. Assessment of lamellar level properties in mouse bone utilizing a novel spherical nanoindentation data analysis method. J Mech Behav Biomed Mater. 2012;13:102–17. https://doi.org/10.1016/j.jmbbm.2012.03.018 PMID: 22842281 28. Hertz H. On the contact of rigid elastic solids and on hardness. Misc Pap. 1896. pp. 163–83. 29. Oliver WC, Pharr GM. An improved technique for determining hardness and elastic modulus using load and displacement sensing indentation experiments. J Mater Res. 1992;7:1564–83. https://doi.org/10.1557/JMR.1992.1564 30. Chen Z, Diebels S. Parameter re‐identification in nanoindentation problems of viscoelastic polymer layers: Small deformation. Z Angew Math Mech. 2012;93(2–3):88–101. https://doi.org/10.1002/zamm.201100170 31. Kontomaris SV, Stylianou A, Nikita KS, Malamou A. A discussion regarding the application of the hertz contact theory on biological samples in AFM nanoindentation experiments. Micro Nanosyst. 2021;13(1):42–8. https://doi.org/10.2174/1876402912666200115160207 32. Poon B, Rittel D, Ravichandran G. An analysis of nanoindentation in linearly elastic solids. Int J Solids Struct. 2008;45(24):6018–33. https://doi. org/10.1016/j.ijsolstr.2008.07.021 33. Remache D, Semaan M, Rossi JM, Pithioux M, Milan JL. Application of the Johnson-Cook plasticity model in the finite element simulations of the nanoindentation of the cortical bone. J Mech Behav Biomed Mater. 2020;101:103426. https://doi.org/10.1016/j.jmbbm.2019.103426 PMID: 31557661 34. Pathak S, Kalidindi SR. Spherical nanoindentation stress–strain curves. Mater Sci Eng R Rep. 2015;91:1–36. https://doi.org/10.1016/j. mser.2015.02.001 35. Yan C, Geers MGD, Giuntini D. Extracting flow curves from spherical nanoindentation: The case of supercrystalline nanocomposites. Mater Des. 2025;259:114903. https://doi.org/10.1016/j.matdes.2025.114903 36. Guha I, Zhang X, Rajapakse CS, Chang G, Saha PK. Finite element analysis of trabecular bone microstructure using CT imaging and continuum mechanical modeling. Med Phys. 2022;49(6):3886–99. https://doi.org/10.1002/mp.15629 PMID: 35319784 37. Donnelly E, Baker SP, Boskey AL, van der Meulen MCH. Effects of surface roughness and maximum load on the mechanical properties of cancellous bone measured by nanoindentation. J Biomed Mater Res A. 2006;77(2):426–35. https://doi.org/10.1002/jbm.a.30633 PMID: 16392128 38. Pepe V, Oliviero S, Cristofolini L, Dall’Ara E. Regional nanoindentation properties in different locations on the mouse tibia from C57BL/6 and Balb/C female mice. Front Bioeng Biotechnol. 2020;8:478. https://doi.org/10.3389/fbioe.2020.00478 PMID: 32500069 39. MTS Systems Corporation. TestWorks 4 Software for Nanoindentation Systems. Oak Ridge, Tennessee, USA: MTS Systems Corporation; 2002. 40. Kim D-G, Jeong Y-H, Kosel E, Agnew AM, McComb DW, Bodnyk K, et al. Regional variation of bone tissue properties at the human mandibular condyle. Bone. 2015;77:98–106. https://doi.org/10.1016/j.bone.2015.04.024 PMID: 25913634 41. Li X, Bhushan B. A review of nanoindentation continuous stiffness measurement technique and its applications. Mater Charact. 2002;48:11–36. https://doi.org/10.1016/S1044-5803(02)00192-4 42. Cheng Y-T, Cheng C-M. Can stress–strain relationships be obtained from indentation curves using conical and pyramidal indenters? J Mater Res. 1999;14(9):3493–6. https://doi.org/10.1557/jmr.1999.0472

PLOS One | https://doi.org/10.1371/journal.pone.0361283 October 23, 2026 25 / 25 43. Juliano TF, Vanlandingham MR, Weerasooriya T, Moy P. Extracting Stress-Strain and Compressive Yield Stress Information from Spherical Indentation. 2007 [cited 27 Apr 2026]. Available: https://apps.dtic.mil/sti/html/tr/ADA472755/ 44. Francis HA. Phenomenological analysis of plastic spherical indentation. J Eng Mater Technol. 1976;98:272–81. https://doi.org/10.1115/1.3443378 45. Nesbitt DQ, Nelson ML, Shannon KS, Lujan TJ. Dots-on-plots: A web application to analyze stress–strain curves from tensile tests of soft tissue. J Biomech Eng. 2022;145. https://doi.org/10.1115/1.4055593 46. Dassault Systèmes Simulia Corp. ABAQUS. Providence, RI, USA: Dassault Systèmes; 2024. Available from: https://discover.3ds.com/ 47. The MathWorks, Inc. MATLAB. Natick, MA, USA: The MathWorks Inc.; 2024. Available from: https://www.mathworks.com 48. Asgari M, Abi-Rafeh J, Hendy GN, Pasini D. Material anisotropy and elasticity of cortical and trabecular bone in the adult mouse femur via AFM indentation. J Mech Behav Biomed Mater. 2019;93:81–92. https://doi.org/10.1016/j.jmbbm.2019.01.024 PMID: 30776678 49. Aitkenhead A. Mesh Voxalization. MATLAB Central File Exchange; 2026. Available from: https://www.mathworks.com/matlabcentral/ fileexchange/27390-mesh-voxelisation 50. Zobaer SMT, Sutradhar A. An energy-based method for interface connectivity of incompatible microstructures through parametric modeling. Comput Methods Appl Mech Eng. 2020;370:113278. https://doi.org/10.1016/j.cma.2020.113278 51. Dong G, Tang Y, Zhao YF. A 149 line homogenization code for three-dimensional cellular materials written in matlab. J Eng Mater Technol. 2018;141. https://doi.org/10.1115/1.4040555 52. Helgason B, Gilchrist S, Ariza O, Vogt P, Enns-Bray W, Widmer RP, et al. The influence of the modulus-density relationship and the material mapping method on the simulated mechanical response of the proximal femur in side-ways fall loading configuration. Med Eng Phys. 2016;38(7):679– 89. https://doi.org/10.1016/j.medengphy.2016.03.006 PMID: 27185044 53. Bushby AJ, Ferguson VL, Boyde A. Nanoindentation of bone: Comparison of specimens tested in liquid and embedded in polymethylmethacrylate. J Mater Res. 2004;19:24. https://doi.org/10.1557/jmr.2004.19.1.249 54. Autefage A, Palierne S, Charron C, Swider P. Effective mechanical properties of diaphyseal cortical bone in the canine femur. Vet J. 2012;194(2):202–9. https://doi.org/10.1016/j.tvjl.2012.04.001 PMID: 22595311 55. Lee K-L, Baldassarri M, Gupta N, Pinisetty D, Janal MN, Tovar N, et al. Nanomechanical characterization of canine femur bone for strain rate sensitivity in the quasistatic range under dry versus wet conditions. Int J Biomater. 2012;2012:415230. https://doi.org/10.1155/2012/415230 PMID: 23365577 56. Lin ZX, Xu Z-H, An YH, Li X. In situ observation of fracture behavior of canine cortical bone under bending. Mater Sci Eng C Mater Biol Appl. 2016;62:361–7. https://doi.org/10.1016/j.msec.2016.01.061 PMID: 26952434 57. Brekhus C, Labus K, Seguin B, Puttlitz C, Gadomski B. Patient-specific finite element modeling for fracture risk prediction in a canine model of osteosarcoma. Ann Transl Med. 2024;12:5. https://doi.org/10.21037/atm-23-1699 58. Kang Q, An YH, Friedman RF. Mechanical properties and bone densities of canine trabecular bone. J Mater Sci Mater Med. 1998;9(5):263–7. https://doi.org/10.1023/a:1008852610820 PMID: 15348882 59. Van Rietbergen B, Müller R, Ulrich D, Rüegsegger P, Huiskes R. Tissue stresses and strain in trabeculae of a canine proximal femur can be quantified from computer reconstructions. J Biomech. 1999;32(4):443–51. https://doi.org/10.1016/s0021-9290(99)00024-x PMID: 10213036 60. Farage-O’Reilly SM, Cheong VS, Pickering E, Pivonka P, Bellantuono I, Kadirkamanathan V, et al. The loading direction dramatically affects the mechanical properties of the mouse tibia. Front Bioeng Biotechnol. 2024;12:1335955. https://doi.org/10.3389/fbioe.2024.1335955 PMID: 38380263 61. Sadoughi S, Bevill G, Morgan EF, Palepu V, Keaveny TM, Wear KA. Biomechanical structure–function relations for human trabecular bone — Comparison of calcaneus, femoral neck, greater trochanter, proximal tibia, and vertebra. Comput Methods Biomech Biomed Engin. 2023;26:508– 16. https://doi.org/10.1080/10255842.2022.2069465